# NORDEND: a morning of thermal cycle, and a camera jolt at noon
|
|
|
|
The selection runs from 05/11 06:00 to 05/11 12:00 (UTC), without hints. The question: what do the corrected curves show over this morning, and what is not yet labeled?
|
|
|
|
## What the data show
|
|
|
|
- **06:30 → noon (and until the next day): the thermal cycle of the camera.** Already labeled (NORDEND-234).
|
|
- The housing heats from about 19 °C to 28 °C. The camera turns: the pan drops, the tilt rises, the scale increases.
|
|
- The whole scene, references included, slides together in the image. The compensation almost absorbs it: a drift of a few hundredths of a px remains on the targets of the right edge (PR18, PR16, PR15, PR13 in `corr_x`) and on PR04 and PR08.
|
|
- Cause: **strongly supported**. The pose follows the housing temperature, and the rock face does not move with the temperature.
|
|
- Commands: `overview.py data/NORDEND --start 2026-11-05T04:00Z --end 2026-11-05T14:00Z --min 1`; `metrics.py` on the same window.
|
|
- **12:00, one measurement: a camera jolt that the compensation does not erase.** New label, Displacement.
|
|
- The rotation and the tilt jump then come back at 12:15. The raw positions of all sensors, references included, jump together then come back.
|
|
- The `corr_y` of PR01, PR10, PR02, PR04 and PR07 drops clearly, by 5 to 7 times their noise. The `corr_x` of PR01 and PR02 rises a little. Everything comes back at 12:15.
|
|
- What does not move: no reference lost, no rejection outside CTR01 (as usual), nothing in front of the targets on the image of 12:00.
|
|
- Cause: a jolt of the camera or its mount, **consistent with** the pose; not seen, therefore not established.
|
|
- Commands: `ranges.py data/NORDEND --start 2026-11-05T04:00Z --end 2026-11-05T14:00Z --columns corr_x,corr_y --rolling 4 --instants 3` (8 sensors off level at 12:00 only); `overview.py ... --rigid 2026-11-05T06:00Z`.
|
|
- **The missing points**: all already labeled.
|
|
- CTR01 is rejected over almost the whole range: Target issue, NORDEND-230.
|
|
- PR09 is rejected at times until 09:30: thread of the spider web seen at night, NORDEND-232.
|
|
- Command: `inventory.py data/NORDEND --start 2026-11-05T06:00Z --end 2026-11-05T12:00Z`.
|
|
- **09:45, one measurement**: PR09, PR10 and PR12 drop a little in `corr_y`, then come back.
|
|
- It is the moment when the thermal drift goes fastest, without a pose jolt.
|
|
- I leave it in the thermal cycle, whose label already cites it.
|
|
|
|

|
|
The `corr_y` of PR01, PR02, PR04, PR07 and PR10 dips at 12:00 (grey zone) and comes back at 12:15. The small dip of 09:45 is also visible, weaker.
|
|
|
|

|
|
At the top, the pose drifts all morning with the heat (thermal cycle). At 12:00, the rotation, the tilt and the raw position of all sensors make a one-measurement peak, then come back.
|
|
|
|

|
|
Sunny day. The targets are in the shade, at the bottom right, and nothing is in front of them.
|
|
|
|

|
|
The slow drift of the right edge (PR18, PR16, PR15, PR13) over the morning: it is the rest of the thermal cycle.
|
|
|
|
## What remains not established
|
|
|
|
- The cause of the jolt of 12:00: a brief movement of the camera or its mount, without an image of the instant that shows it. A second jolt of the same shape follows at 12:30, outside the selection and not read.
|
|
- The end of NORDEND-232 (PR09) is perhaps one step too early: PR09 is still a little low at 10:00.
|
|
- The back-and-forth of the `error_value` of CTR02, PR01 and PR09 all morning, without effect on the curves, remains unexplained.
|
|
|
|
## Labels
|
|
|
|
- 05/11 11:45 → 12:15, Displacement: one-measurement jolt of the camera at 12:00, several targets drop in `corr_y` and come back; not a movement of the structure, points to ignore, camera to monitor if it repeats.
|
|
- Kept as they are: NORDEND-229, NORDEND-234 (Thermal displacement), NORDEND-230 (Target issue, CTR01), NORDEND-232 (Obstruction, PR09).
|