# Labels: WYOMING, 2026-11-06T08:05Z → 2026-11-16T06:27Z (UTC)
Measurements of the range: 2026-11-06T08:15Z → 2026-11-16T06:15Z, 15 min, 951 instants. 16 sensors: 3 references (RD, target_12, target_13), 13 targets. No image quality metrics (export columns peak to snr empty). One image per hour, on the hour. Temperature: only `temperature_deg_c` is filled; I call it the housing temperature (`labeling-rules.md` §5). No earlier labels (`labeling/auto/WYOMING.jsonl` does not exist).
**Revision after the user's remark on the weather.** I added the MeteoSwiss hourly weather at Genève-Cointrin (station GVE, 4.9 km from "Genève", the place given for WYOMING in `~/aimsight-data/extraction/stations.txt`). I fetched it with `python3 weather/meteoswiss.py "Genève" 2026-11-05 2026-11-16T07:00` from `~/aimsight-data`, into `work/weather_geneve.csv` (05/11 → 16/11 07:00, for the scripts). Since the instructions now require it, the weather of the exact range is also in `work/weather.csv` (`python3 weather/meteoswiss.py "Genève" 2026-11-06T08:05 2026-11-16T06:27`; stderr: station GVE Genève / Cointrin, 4.9 km, 411 m; 238 hours). It is the weather a few km away; the images prevail. What it changed:
1. The housing temperature follows the **outside air** (r = +0.82, no lag) and not the sun (r = +0.02 with radiation, −0.11 with sunshine). Under the bise (13–14/11) the housing cools more than the air, and the shift of the nearest prism follows the housing then too (r = +0.96 with the housing, +0.83 with the air, best at lag 0 h). The moving element therefore follows the camera's own temperature within the hour, which a massive pier would not. This strengthens "thermal movement of the camera mount" for the 8 cycles.
2. (Withdrawn after the expert's review: the agitation episodes are no longer labelled, see §1.) The agitation of the far prisms follows the **cold of the air** (r = −0.63 with the air temperature, +0.05 with the wind). It hits only the long, low sight lines over the river. I now label it apart, as 2 **Visibility** episodes (turbulence over the warmer water, "consistent with"). The one-measurement jump of target_12/13 at 14/11 21:00 is the strongest moment of the bise episode and is named in it; the one of 07/11 05:00 has its own Displacement label again since the 07/11 morning episode was removed.
3. The two dawn transients (08/11, 14/11) fall at the coldest air of a clear night, at sunrise, inside the agitation. A bending of the long sight lines over the river now competes with a fast camera movement. Neither is established, so I moved them from Thermal displacement to **Displacement** (cause not established, both hypotheses stated).
4. The occultation of target_14 (11/11) covers the rain of that morning and ends soon after it stops: water on the prism is likely, and the description says so. The 11/11 07:15 jump falls at the start of the rain, which is now cited as possible. For the 11/11 14:45 passage the rising gusts were checked: the nearer prisms do not move in the raw image, which rules out a camera shake.
**The key to the hint (unchanged).** RD has no spot of its own. Its position falls on a dark part of the nearest pier, next to target_01's prism (`fig_rd_target01.png`). RD and target_01 have the same `error_value` at every instant and the same raw movement (`overview.py --rigid`), so RD is a pattern on target_01's prism: twins, the nearest prism. target_12 and target_13 are the farthest prisms. With temperature the nearest prism moves sideways against all the others, and the similarity fitted on RD + target_12/13 spreads this over the image. target_14, target_15 and target_02, which lie in the image between RD and the far references, take it in their corr_x. target_01, being RD's own prism, does not.
## 1. My labels
### Thermal cycles: 06/11 09:15 → 07/11 07:30; 07/11 07:30 → 08/11 07:00; 08/11 07:00 → 09/11 09:45; 09/11 09:45 → 10/11 04:45; 10/11 04:45 → 13/11 09:30; 13/11 09:30 → 14/11 07:00; 14/11 07:00 → 15/11 04:15; 15/11 04:15 → 16/11 06:15
- **Phenomenon of the catalogue**: "The camera drifts away when the temperature of its housing drops, without a daily cycle" / "The camera moves through a thermal effect". The poor compensation is a new variant: the reference network mixes the nearest and the farthest prisms, so a small movement of the mount becomes a parallax that passes into the targets between them.
- **Precedents**: CLARIDEN-5, -13, -27, -43 (reviewed): a sheltered station without a daily cycle, cut at the turning points of the housing temperature. NORDEND-83/88 (reviewed): "thermal cycle of the camera, poorly compensated", outward and return in one label, labels following each other without rest.
- **Family**: Thermal displacement. The shift follows the housing temperature and comes back with it at equal temperature: dx_RD +0.47…+0.58 at 26.8–27 °C on 07/11, 09/11, 10/11 and 11/11, and −0.05…+0.05 near 24.4 °C on 06/11, 08/11 and 13/11, with up to ~0.3 px of hysteresis. It follows the housing better than the air, at lag 0, and the housing follows the outside air, not the sun.
- **Measured**: `metrics.py` 05/11 → 16/11: r(temperature, cam_scale) = +0.97, r(cam_pan) = −0.94, r(tgt_corr_y) = +0.84. `overview.py --rigid 2026-11-06T09:00Z`: RD and target_01 dx −0.86…+0.73 px. target_02, target_14 and target_15 move less than ±0.41, and the far targets less than ±0.3. `scripts/table.py`: corr_x of target_14 from +0.69 (14/11 06:00) to −0.66 (11/11 12:00), target_01 within ±0.16. Turning points at 15 min: 06/11 09:15, 07/11 07:30, 08/11 07:00, 09/11 09:45, 10/11 04:45, 13/11 09:30, 14/11 07:00, 15/11 04:15. 10/11 → 13/11 stays one label: a plateau on 11/11 and a flat stop on 12/11, with no change of direction. `scripts/weather.py`: r(dx_RD, housing) = +0.96, r(dx_RD, air) = +0.83, r(housing, air) = +0.82, r(housing, radiation) = +0.02. The lag of dx_RD on the housing is best at 0 h. Weather of each cycle (MeteoSwiss): grey and mild 06/11; sunny midday then a clear calm night near 0 °C 07–08/11; sunny morning 08/11; mild, overcast, rain at times 10–12/11; bise (NE, gusts to ~50 km/h, dry air) from the night of 12–13/11 to 14/11; SW wind and mild air 15/11.
- **Images**: 06/11 12:00 whole image (`fig_scene_20261106T1200Z.jpg`); zone thumbnails 06/11 12:00, 14/11 03:00 (`fig_rd_target01.png`); far piers 07/11 07:00, 08/11 06:00/07:00/08:00, 11/11 07:00/08:00/14:00/15:00: nothing in front.
- **Confidence**: high on the family and on what moves; medium on the exact cut points (±1 measurement) and on the mechanism (camera mount most likely).
### Visibility: none (all removed, according to the expert)
- I had labelled four episodes of agitation of the far prisms in cold air (06/11 09:45 → 15:00; 07/11 02:45 → 10:00; 07/11 20:45 → 08/11 13:00; 13/11 02:45 → 15/11 14:00). The expert sees nothing in the data or the images; all four are removed. The statistics behind them stay in `scripts/agitation.py` (hourly median of |corr_y step| of target_07…11 a few hundredths of a pixel higher in cold air, r = −0.63 with the air temperature, nothing with the wind). They are a correlation, not a disturbance seen on the curves.
- The two one-measurement jumps of target_12/13 that I had merged into these episodes have their own Displacement labels again: 07/11 04:45 → 05:15 and 14/11 20:45 → 21:15.
### Displacement: 08/11 06:45 → 08:30 and 14/11 07:00 → 08:30 (dawn transients)
- **Phenomenon of the catalogue**: none fits exactly. Close to "A step of the camera that the compensation does not erase", but this one returns.
- **Precedents**: none with this signature.
- **Family**: Displacement (cause not established). Both come at dawn after the two coldest nights, at the coldest air hour, and end as the sun comes out (sunshine from the 08:00 hour at Cointrin both days). Two hypotheses remain: (a) a lateral bending of the long sight lines through the cold air over the water, since all the far prisms shift together and the near one does not; (b) a fast camera movement as the housing warms abruptly (+1.4 °C and +0.8 °C in the 07:00 hour, with no change in power or load in `metrics.py`).
- **Measured**: `scripts/far.py`: far prisms 03–13 raw x −0.51/−0.67/−0.38 at 08/11 07:15/07:30/07:45, back at 08:00. corr_x target_14 +0.36 (06:45) → −0.75 (07:15) → −0.09 (08:15) → +0.14 (08:30). On 14/11: far x +0.32 → −0.30 (07:45) → +0.06 (08:00); corr_x target_14 0.68 → −0.04 (07:45) → 0.40 (08:30).
- **Images**: 08/11 07:00 (haze over the river, sun on the facades), 14/11 07:00 (sun on the facades). No image during the shift.
- **Confidence**: high on the event, low on the cause.
### Displacement: 11/11 07:00 → 07:30
- target_12/13 jump alone, `error_value` 0.26/0.21 against ~0.08; corr_y of 03–11 −0.08…−0.18; back at the next measurement. The air is mild (11.7 °C, not a cold-air agitation hour); the rain begins in that hour. Cause not established (rain veiling the far references, or a partial passage). Images 07:00 and 08:00: nothing in front. Confidence: high on the event, low on the cause.
### Obstruction: 07/11 13:00 → 13:30, 15/11 14:00 → 14:30, 11/11 14:30 → 15:00
- "A pass-by hides the targets for the length of one measurement", deduced from the signature: one measurement, a group rejected, points jumping, all back at the next. On 11/11 14:45 everything beyond a given pier is lost (target_07–13, references included: no pose, the corr of 02–06 meaningless). The raw positions of the nearer prisms barely move (target_06 ≤ 0.45 px), which rules out a camera shake by the gusts rising then (Cointrin 17.6 → 28 km/h). A crossing of the line of sight, such as a boat on the river, fits that geometry but is not seen. On 07/11 and 15/11 there was some wind (gusts 18 and 33 km/h); nothing else moved. Confidence: medium (no image at the instants).
### No data: 10/11 08:15 → 09:00
- 08:30 and 08:45 are missing for all sensors, and ALASKA and NADELHORN miss exactly the same instants. WYOMING `last_sync` lists 08:45, BusVoltage is 14.1 V, and the images at 08:00 and 09:00 exist. Common cause outside the station, not established. Confidence: high.
### Obstruction: 11/11 09:30 → 14:15 (target_14)
- "An obstacle covers part of the spot". On the 12:00 thumbnail part of target_14's spot is darkened; it is whole at 07:00, 10:00, 13:00 and 15:00, and target_15 is always intact (`fig_target14_occultation.png`). `error_value` 0.077 → 0.252 (12:00) → 0.071 (13:45). corr_x(14) − corr_x(15) −0.32 at 12:00; corr_y −0.21 at 12:00, back by 14:15. Rain at Cointrin 07:00–12:00 (1.9 mm at its heaviest, in the 09:00 hour) and none from 13:00, matching the rise and the end: water on the prism is likely. Family Obstruction, since a single spot is hidden (`families.md`: "under a single spot, it is an obstacle"). Confidence: high on the occultation, medium on the water.
## 2. What I left without a label
- 06/11 09:45–15:00: a slight agitation of the far targets (hourly |corr_y step| 0.025–0.040 at 10:00, 11:00, 14:00, against 0.010–0.020 around it), air 8–10 °C. Labelled Visibility in my second version, removed: according to the expert, nothing shows in the data or the images. Too weak to be told from the ordinary noise.
- 14/11 10:15: target_12/13 opposite raw jumps and corr_y of 07–10 +0.10…+0.14 for one measurement; too small to stand out from the noise of these days.
- The agitation of the far targets in cold air (07–08/11, 13–15/11): a few hundredths of a pixel more from one measurement to the next; not labelled, according to the expert.
- 09/11 night (air 8.1–8.8 °C): agitation of the far targets 0.02–0.03, just above the mild-day level. Below what I bounded as episodes; borderline.
- 10/11 00:00–09:00: the raw y steps of target_12/13 rise during the night rain (up to 0.18 at 03:00) while the far targets' corr stay calm; nothing on the curves.
- `error_value` flags on target_14/15 alone (07/11, 08/11, 15/11), with corr within ±0.07; the slight rise of target_14's `error_value` from 10/11 10:45 to 11/11 08:00, without corr effect.
- The camera pose is missing from 16/11 00:30 to the end while the corr go on: an export matter.
- Tiny one-step deviations of RD/target_12/13 corr (references, own noise).
## 3. The documentation
- **Indications from the expert**: 06/11 09:45 → 15:00, no disturbance in the data or the images; 07/11 02:45 → 10:00, too sensitive; then all the Visibility agitation labels removed, the expert seeing nothing in the data. Lesson: an agitation of a few hundredths of a pixel, found by statistics (steps per hour, correlation with the air) and not visible on the curves, is not labelled. The expert also questioned the thermal cycle 06/11 09:15 → 07/11 07:30. I kept it: corr_x of target_14/15 move by 11–15 noises, the same signature as the other cycles in smaller, and `labeling-rules.md` §1 (D-117, 5-noise rule) asks for it; it awaits the expert's decision. Lesson: an agitation episode is labelled only when it stands clearly above the noise on the curves themselves, not on a correlation with the air temperature alone.
- **Indication from the user**: the weather data. It was not in the station folder, nor in `tools/GUIDE.md`, `tools/DATA.md` or the labeling knowledge, so I had not looked for it. It sits in `~/aimsight-data/weather/meteoswiss.py`, with the place of each station in `~/aimsight-data/extraction/stations.txt`, and is shown by the Data page. `tools/GUIDE.md` should get a weather tool or a line (air temperature, rain, wind, sunshine at the nearest MeteoSwiss station). `reading-rules.md` §3 says the housing temperature is "a witness for the lens and the mount, not for the structure nor the air". Here it follows the air closely (r = +0.82) except under the bise, which is worth recording.
- **What helped**: `families.md` "Thermal displacement or Displacement" (return at equal temperature); the CLARIDEN tunnel precedents for cutting without a daily rhythm; `reading-rules.md` §2 and §5 (`--rigid` first); `tools/DATA.md` (`x, y` are not the centroid), which made "RD is a pattern beside its prism" plausible; `reading-rules.md` §6 "a twin of a reference".
- **What was missing**: a WYOMING row in `stations.md`. It should say: a bridge seen from beneath its deck along a river, in Genève; targets on the piers; RD the twin of target_01 (same prism, nearest pier); target_12/target_13 the farthest prisms; the targets between them in the image (target_02, target_14, target_15) take the thermal parallax; only `temperature_deg_c`; one image per hour. Two phenomena are missing from the catalogue: "references at very different depths, so a small movement of the mount becomes a deformation passed into the targets between them", and "agitation of the long sight lines over water when the air is colder than the water, without the `error_value` rising".
- **Contradicted or unclear**: the catalogue line "Atmospheric turbulence… `error_value` up", and the boundary "without the `error_value` rising, an agitation… is the camera heating". Here the agitation is in the air (it follows the cold air, only on the long sight lines over the water) with a flat `error_value`. I chose Visibility against the letter of that boundary and said so in each label.
- The hint "parallax does not fit target_01": target_01 is RD's own prism, so it moves with the reference and cannot show the parallax that RD passes into the others.
- **Instructions changed during the session** (the weather fetched every time; labels detailed for retrieval; a short report in plain words on an imposed outline, with a GIF when the cause is seen over time). Labels kept as they were (already detailed); report rewritten on the new outline, with a GIF of target_14 on 11/11 07:00 → 15:00 (`target14_occultation_20261111.gif`, zone 1990,725,300,80) and the main figure redrawn in plain words.
## Difficulties
- `tools/GUIDE.md` §Conventions limits Bash to the tools without scripts or loops, while the request allows scripts; I followed the request.
- The weather source was not documented in my instructions at the start; the user pointed to it, and the instructions now require it (section "The weather").
- Hourly images only, no image quality metrics: the brief events have no image at their instant.
## Sources read
`instructions/analyst.md`; `tools/GUIDE.md`; `tools/DATA.md`; `labeling/families.md`; `labeling/labeling-rules.md`; `labeling/reading-rules.md`; `labeling/stations.md`; precedents (`labeling/scripts/precedents.py`, three queries); `request.json`; WYOMING data through `inventory.py`, `overview.py` (default and `--rigid`), `metrics.py` (temperatures; power, current, load), `summary.py`, `ranges.py --rolling 4 --instants 2`, `thumbnails.py`, whole images 06/11 12:00, 08/11 07:00, 14/11 07:00; raw CSVs of ALASKA, NADELHORN and the other stations on 10/11 08:00–08:49; WYOMING `last_sync`, `BusVoltage`; the MeteoSwiss weather (`~/aimsight-data/weather/README.md`, `meteoswiss.py`, `extraction/stations.txt`, `app/server/station.py` for the link); my scripts `scripts/table.py`, `far.py`, `instants.py`, `weather.py`, `agitation.py`, `figure.py`, `figure_weather.py`.