19 lines
14 KiB
JSON
19 lines
14 KiB
JSON
{"start": "2026-10-22T03:15Z", "end": "2026-10-22T03:45Z", "family": "Displacement", "description": "The corr_x of Sellette 4 alone jumps slightly upward from one measurement to the next, on the night of the 22nd at 3h30, and stays there until the end of the month; at the same moment its error_value goes down a little and stays lower. Sellette 5, its neighbors and the two references show nothing, the camera does not move and nothing hides it at that hour (no other episode). Its level joins the one it had from the 9th to the 15th. The housing temperature drops clearly on those days, as from the 9th to the 15th, but the jump happens from one measurement to the next, with a step in its error_value: link not established. Cause not established: the spot of Sellette 4 may have changed appearance, or the target may have moved. Small, without established movement of the structure: to be monitored.", "review": "2026-11-17"}
|
|
{"start": "2026-10-22T11:15Z", "end": "2026-10-22T13:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in late morning, one measurement then four: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established; r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
|
{"start": "2026-10-23T03:45Z", "end": "2026-10-23T09:15Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold at the end of the night then all morning, after a slow rise of its error_value in the night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established (dampness on the prism or morning light, without proof); r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
|
{"start": "2026-10-23T12:15Z", "end": "2026-10-23T20:15Z", "family": "Visibility", "description": "Mist in the afternoon: the error_value of p1_r rises and the camera pose goes wrong, the corr_x of Sellette 4, Sellette 5 and Sellette 6 jumps clearly; then r1_r (with Pont Ernen), p1_r (with Sellette 3), Sellette 4 and Sellette 5 are rejected at times until the evening, the camera is often no longer registered. Seen on the 15:00 image: mist over the valley, milky scene. Back in the evening. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-10-23T22:00Z", "end": "2026-10-24T01:45Z", "family": "Visibility", "description": "At night, the error_value of the two references, p1_r and r1_r, rises without exceeding the threshold: the camera pose goes wrong (mostly the tilt) and the corr of Sellette 4 and Sellette 5 shifts (corr_x upward, corr_y downward, clearly on Sellette 4), then returns around 1h30 when p1_r becomes sharp again. Thumbnails of 21:00, 23:00, 00:30 and 03:00: nothing in front of the spots, that of r1_r, tiny, getting weaker and weaker; r1_r stays poorly seen until its loss in the morning. Cause not established (dampness probable, like the neighboring episodes). Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-10-24T07:00Z", "end": "2026-10-24T14:45Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold all morning and the early afternoon: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established (dampness on the prism or morning light, without proof); r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
|
{"start": "2026-10-24T21:45Z", "end": "2026-10-25T21:15Z", "family": "Visibility", "description": "Rain on the night of the 24th to the 25th and during the day of the 25th: the error_value of all the sensors rises very high; r1_r (with Pont Ernen) is rejected almost throughout the episode, p1_r (with Sellette 3) at night, Sellette 4, Sellette 5, Massif 2 and Sellette 6 almost always: the camera is almost no longer registered, almost all the curves are missing, and the kept measurements jump (clearly on Sellette 4 in late morning). Seen on the 03:00 image: drops lit by the infrared in front of the lens, a single visible spot. Back on the evening of the 25th, Sellette 4 the last, an hour after the others. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
|
|
{"start": "2026-10-26T08:30Z", "end": "2026-10-26T12:00Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in the morning, after a slow rise of its error_value all night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established (dampness on the prism or morning light, without proof); r1_r is a tiny spot, day and night. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
|
{"start": "2026-10-26T11:45Z", "end": "2026-10-26T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-26T14:30Z", "end": "2026-10-26T15:15Z", "family": "No data", "description": "Two measurements absent for all sensors, and no image; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01), and their metrics are also missing at the same minutes: a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 15:00.", "review": "2026-11-17"}
|
|
{"start": "2026-10-27T01:45Z", "end": "2026-10-27T11:45Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise slowly from the evening of the 26th, then pass above the threshold in the morning. During the night, its position in the image slides relative to the targets (ensemble.py --rigide) and distorts the camera pose, while the housing temperature stays stable: this is not the return of the thermal cycle of the 26th; from 02:00, the corr_x of Sellette 4 and Sellette 5 deviates at times, and their corr_y at 05:00. In the morning, r1_r is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 6, Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. One measurement is missing for all sensors at 09:15. Seen on the thumbnails: the spot of r1_r weakens in the night, disappears at 08:00 and 10:00 and returns in the afternoon; no obstacle; dampness on the prism or morning light, cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
|
{"start": "2026-10-27T09:00Z", "end": "2026-10-27T09:30Z", "family": "No data", "description": "One measurement absent for all sensors; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NORDEND): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
|
|
{"start": "2026-10-27T11:30Z", "end": "2026-10-27T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 6 goes down clearly in the afternoon, that of Sellette 5 a little, the corr_y of Sellette 5 rises a little, and everything returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-28T07:00Z", "end": "2026-10-28T10:30Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold in the morning, one measurement then nine, after a slow rise of its error_value all night: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 (and of Sellette 6 at the first loss) jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Same scenario as the previous mornings; cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
|
|
{"start": "2026-10-28T10:15Z", "end": "2026-10-28T19:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day, small: with the clear rise of the housing temperature in the morning, the camera pose turns (mostly the rotation, the tilt a little, the pan hardly moves) until the early afternoon, then returns in the late afternoon; the corr_y of Sellette 5 rises during the day and comes back toward its night level in the evening, the corr_x of Sellette 5 and Sellette 4 rise a little with it. The start is hidden under the loss of r1_r of the morning (separate label); the pose has already turned at the first registration after it. Deduced: the pose and the curves follow the housing temperature and come back with it, error_value at its level, the references calm. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-18"}
|
|
{"start": "2026-10-29T06:45Z", "end": "2026-10-29T18:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-30T07:45Z", "end": "2026-10-30T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|
|
{"start": "2026-10-31T06:45Z", "end": "2026-10-31T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
|