- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
41 lines
3.3 KiB
Markdown
41 lines
3.3 KiB
Markdown
# MICHIGAN: cold mornings, 23 October to 1 November
|
|
|
|
You asked to requalify the labels of 23 October 20:00 → 1 November 00:00 (UTC) under the new rule: keep only what stands out from the ordinary noise of the corrected curves.
|
|
|
|
## In short
|
|
|
|
Four cold mornings (26, 28, 29 and 30 October) push the corrected curves in x clearly out of their noise: do not trust them there. The other moves of the week (24, 27 and 31 October) stay within the noise and are no longer labelled. No real movement of the structure is seen.
|
|
|
|
## What happened
|
|
|
|
**Cold mornings move the camera (26, 28, 29, 30 October).** The station is indoors. Each time the temperature inside the camera housing drops by one to four degrees, the camera nods forward and its image shrinks slightly. All the targets shift together in the image. The camera correction now rests on only two reference prisms (the third is lost), so part of this movement passes into the corrected curves of every target. The error shows mostly in x and grows with the distance of the target. On the far targets (40 to 50 m) the curves in x drop by about 2 to 3 mm on 26 October and 4 to 5 mm on 28 October. On 29 and 30 October, when the housing was coldest, they drop by 8 to 10 mm. On the near targets (9 m) the drop stays under 1 mm. The curves come back when the housing warms up. Cause confirmed by the curves, the camera position and the temperature; the images show nothing in front of the targets. No weather data exist for this station.
|
|
|
|

|
|
|
|
Look at the grey bands in the top panel: the far targets drop together and come back after each band, while the near target (blue, 9 m) hardly moves.
|
|
|
|
## What to do
|
|
|
|
Restore the third reference prism (REFPOU22, rejected at every measurement): with three references, the correction should absorb these camera movements again.
|
|
|
|
## Not established
|
|
|
|
The move of 26 October goes past the noise only if the noise is measured outside the much stronger cold mornings of 28 to 30 October (7 noises against 4.7). It was kept on that reading. A calmer stretch of data from this station would settle the size of its true noise.
|
|
|
|
## Requalification
|
|
|
|
Kept 4, rewritten 0, removed 3.
|
|
|
|
- MICHIGAN-20 (23 Oct 20:00 → 25 Oct 00:00, Thermal displacement): removed; the camera moved with the temperature but the corrected curves stay within the noise, 2.7 noises at most (4.0 with the quieter noise), about 1 to 1.5 mm.
|
|
- MICHIGAN-12 (26 Oct 20:00 → 27 Oct 20:00, Displacement): removed; the rise in y reaches 3.2 noises (5.0 at most on a level skewed by the month's slow drift, not beyond), about 2 mm on the far targets.
|
|
- MICHIGAN-21 (31 Oct 00:00 → 16:00, Thermal displacement): removed; under 2 noises, about 1 mm.
|
|
|
|
## Labels
|
|
|
|
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|
|
|---|---|---|---|---|
|
|
| 2026-10-25 16:00 | 2026-10-26 16:00 | Thermal displacement | all, far ones most | cold night, dip in x |
|
|
| 2026-10-28 00:00 | 2026-10-28 16:00 | Thermal displacement | all, far ones most | cold morning, dip in x |
|
|
| 2026-10-28 16:00 | 2026-10-29 16:00 | Thermal displacement | all, far ones most | coldest night, strong dip in x |
|
|
| 2026-10-29 16:00 | 2026-10-30 12:00 | Thermal displacement | all, far ones most | cold night, strong dip in x |
|