Files
aimsight-labeling/auto/analyses/BREITHORN_2026-10-03T0000_2026-11-01T0000/analysis.md
T

9 lines
1.1 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Requalification of the long labels: BREITHORN
Measured with `tools/scripts/ranges.py --columns corr_x,corr_y` (k 5, merge 12h) on each label's range, level = median of the range, noise = own noise (work/ranges_*.txt, work/ranges_all_*.txt).
- **BREITHORN-2**: kept. The drift goes beyond the threshold. POUI19 corr_x stays above its level from 10/10 20:00 to the end of the range (14 measurements), up to +11.1 noises (12/10 12:00, +0.084 px, about +0.3 mm). COLJ19 corr_x goes up to +7.7 noises (11 measurements, 11/10 12:00 → 13/10 04:00). This is a movement of the corr, not missing points.
- **BREITHORN-13**: corrected. The drift goes beyond the threshold: COLH20 corr_x up to +12.6 noises (30/10 04:00, about +0.8 mm), +11.2 noises on 28–29/10; COLJ19 +8.2 noises; POUI19 +7.3 noises; COLI20 +6.5 noises at the end of the range. I applied the correction the period analysts found: COLI22, COLH20''', POUI22 and POUI24 are added to the description. The label loses its review field.
Not checked in this pass (usage limit): the rolling level under the drift (`--rolling`). It is not needed to keep these labels, since the plain level already passes 5 noises.