Instructions to the analyst (support)

Why this range

The client of NADELHORN received two "vertical shift" alarms, on the targets m_c7_mon and m_c10_mon, within 2026-11-18T05:39Z → 11:16Z (UTC). The expert asks the support for a short mail to the client that diagnoses the range: did these targets really move vertically, or is it a measurement artefact (visibility, obstruction, camera / reference movement, thermal), and how sure.

Read the range; widen it if needed to see the level before and after (e.g. from the evening before), and say so.

Your labels

They stay in your output folder (analyst/). Never write in labeling/auto/<STATION>.jsonl nor anywhere else in labeling/.

What you answer me

In a few lines:

  • the facts that answer the question: when (UTC, start / extreme / end), which targets (m_c7_mon, m_c10_mon, and whether others share it), the size of the vertical shift (px and mm if available), whether it comes back, the cause and how sure (confirmed / likely / possible / unknown), what the images show;
  • the path of your analysis, and the paths of the one or two figures that best show the problem to a client (a curve of the corrected vertical position of m_c7_mon and m_c10_mon with a witness target, and/or an image or thumbnails showing the cause); keep them readable for a non-specialist;
  • what you saw outside the question.