aimsight-labeling/auto/analyses/FLORIDA_2026-10-11T0945_2026-10-22T0315/labels.jsonl
T
maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

24 lines
17 KiB
JSON

{"start": "2026-10-11T09:45Z", "end": "2026-10-11T10:15Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold for the duration of one measurement, in the morning: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
{"start": "2026-10-11T09:45Z", "end": "2026-10-11T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T00:30Z", "end": "2026-10-12T01:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps later this night, labeled apart. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T01:45Z", "end": "2026-10-12T03:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement, then again a little later while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back in between only halfway, fully after the second. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 01:00, 02:00 and 03:00. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T03:45Z", "end": "2026-10-12T04:30Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back over the next two. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 03:00 and 04:00. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T06:15Z", "end": "2026-10-12T06:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps earlier this night, labeled apart. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T07:45Z", "end": "2026-10-12T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day, the corr_y of Sellette 4 a little, and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T22:15Z", "end": "2026-10-12T22:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same signature as the jumps of the previous night; no image at that minute. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-13T08:45Z", "end": "2026-10-13T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-14T01:15Z", "end": "2026-10-14T01:45Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
{"start": "2026-10-14T08:45Z", "end": "2026-10-14T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T01:45Z", "end": "2026-10-15T02:45Z", "family": "No data", "description": "Two measurements absent half an hour apart, with a single measurement between them, for all sensors, and no image at those moments; the station nevertheless synchronizes at those moments and its voltage is normal: it is running, the measurements are missing. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
{"start": "2026-10-15T07:45Z", "end": "2026-10-15T22:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 and, a little, that of Sellette 4 go down during the day, until the measurements stop in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T22:45Z", "end": "2026-10-16T10:45Z", "family": "No data", "description": "No measurement for any sensor during the night of 15 to 16, all the curves are missing; no image either, and no system metric over the range. The voltage is normal just before and just after; when the metrics return, a few entries were waiting to be sent. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
{"start": "2026-10-16T13:30Z", "end": "2026-10-16T14:00Z", "family": "No data", "description": "One measurement absent for all sensors, a few hours after the resumption of the 16th, and no image at that moment; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (JUNGFRAU, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-16T14:15Z", "end": "2026-10-16T14:45Z", "family": "No data", "description": "One measurement absent for all sensors, three quarters of an hour after the previous one, and no image at that moment; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-18T05:00Z", "end": "2026-10-18T08:00Z", "family": "Visibility", "description": "End of a night with reduced visibility: the error_value of all the targets and of p1_r rises; p1_r (with Sellette 3), Sellette 4, Sellette 5, Massif 2 and Sellette 6 are rejected at times, the camera is no longer registered for four measurements, and the kept measurements jump. 06:00 thumbnails: all the spots smaller and weaker than the night before, nothing in front; probably dampness or mist, cause not established. Back at daybreak, Sellette 4 the last. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
{"start": "2026-10-18T19:30Z", "end": "2026-10-19T02:15Z", "family": "Visibility", "description": "Start of a night with reduced visibility: from 19h45, the error_value of p1_r rises, the camera pose goes wrong and the corr of Sellette 4 and Sellette 5 jumps; from 21h, Sellette 4, Sellette 5 and Sellette 6 are rejected almost over the whole range, p1_r (with Sellette 3) and Massif 2 most of the time, r1_r twice: the camera is almost no longer registered and the curves are missing; the kept measurements of Massif 2 and Sellette 6 jump. After the rejections end, the corr of Sellette 4 and Sellette 5 stay agitated until about 2h. 22:00 thumbnails: smaller and weaker spots, image of that hour without obstacle; cause not established (dampness probable). Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "Four measurements absent for all sensors, and no image; the station nevertheless synchronizes within the hour and the voltage is normal. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-19T10:45Z", "end": "2026-10-19T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-19T20:45Z", "end": "2026-10-19T21:15Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; measurements resume at the next one. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17"}
{"start": "2026-10-20T09:45Z", "end": "2026-10-20T15:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 and Sellette 6 goes down a little during the day, until the poor-visibility episode of the afternoon. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-20T15:15Z", "end": "2026-10-21T18:30Z", "family": "Visibility", "description": "Long episode of poor visibility while the housing temperature drops: Sellette 4 and Sellette 5 rejected from the afternoon of the 20th, then through the night and the whole day of the 21st p1_r (with Sellette 3) and r1_r (with Pont Ernen) are rejected in turn: the camera is almost no longer registered, most of the curves are missing, and the kept measurements (Massif 2, Sellette 6, Pont Ernen) jump strongly. Seen on the 06:00 image on the 21st: scene veiled, wet leaves; 10:00 thumbnails: weak spots. Rain or mist. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}