Files
aimsight-labeling/auto/analyses/long-labels/CLARIDEN/analysis.md
T
maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

7 lines
1.6 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# Requalification of the long labels: CLARIDEN
- **CLARIDEN-1** (Target issue, P-300-B, 01/10 → 01/11): **kept** as is. P-300-B is rejected at 4070 of the 4070 measurement instants present in the range (`inventory.py --start 2026-10-01T00:00Z --end 2026-11-01T00:00Z`; 6371 of 10137 over the whole period, since 29/09). A target rejected almost always: Target issue.
- **CLARIDEN-14** (Displacement, 06/10 22:00 → 11/10 06:00): **corrected** (description). The drift is beyond the threshold: `ranges.py --k 5` from 05/10 10:30 to 15/10 22:50, the level taken outside the label: D-301-C corr_x out of level up to −19.5 noises (−0.22 px, about −1.1 mm) until 08/10 09:20 before it rises to its later level; D-303-B corr_y up to −15.6 noises (about −0.44 mm) until 08/10 08:40; D-304-C corr_x −9.0, D-303-C corr_y −7.1, D-306-B corr_x +6.4 noises. Bounds and family hold. Correction applied (found by the analyst of the 01/10–11/10 period): "No camera movement" is wrong, the camera tilt drifts over these days and D-303-B, D-303-C, D-304-C, D-301-C follow it (hourly r −0.86 to −0.95, `CLARIDEN_2026-10-01T0000_2026-10-11T0000/analysis.md`); the conclusion becomes "camera to monitor". Review removed.
Sources read: `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `input.jsonl`, the analyses of the three CLARIDEN periods (lines on CLARIDEN-1 and CLARIDEN-14). Commands: `inventory.py` (month, `work/inv_month.txt`), `ranges.py` (corr and corr_mm, 5 targets, `--outside` the label).