- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them) - SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules - long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed - reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert] Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2 lines
1.8 KiB
JSON
2 lines
1.8 KiB
JSON
{"id": "MICHIGAN-3", "start": "2026-10-09T08:00Z", "end": "2026-11-01T00:00Z", "family": "Target issue", "description": "The reference REFPOU22 is lost on 9 October between the 08:00 measurement and the 12:00 one, and does not come back until the end of the month: its error_value rises almost to the maximum, it is rejected at every measurement and its raw positions wander far from its place. On the thumbnails, its spot, sharp at 04:00 and 08:00 on 9 October, has disappeared at 12:00 and does not come back (also seen on 12 October, 20 October and 31 October), while the neighboring spots and REF42, REFG43N are intact; no obstacle is visible. At 12:00 on 9 October, corr_x and corr_y of all the targets jump together and stay shifted, without a step in the raw positions: the compensation now only runs on REF42 and REFG43N, its reprojection error drops to zero and the basis changes. With these two references only, close to each other and far from the targets, the compensation is fragile: the curves of all the targets are more agitated than before, and the slightest deviation of these two references relative to the targets passes, amplified, into all the targets. At the same measurement, NEBRASKA, in the same building as MICHIGAN according to the expert, also loses one of its references (REFCOLH22), whose spot disappears in the same way with no visible obstacle: a cause common to both, in the building, is to be looked for; it is not established. The reference of the same name seen by BREITHORN stays sharp on its images. Cause of the loss not established (prism masked, turned or removed). For the customer: the jump is not a movement, and the corrected curves since 9 October are not very reliable; check the prism of REFPOU22 on site and restore it.", "review": "2026-11-17"}
|