Displacement columns (next use case)

According to the FAQ, the columns of the CSV export are prefixed by the target (e.g. target_06_rch):

  • rch / rcv: displacement corrected for camera movement [mm]. This is the main signal.
  • x / y: raw position in the image [px].
  • rx / ry: relative displacement before camera correction. It is not x - x0.
  • error: target recognition error, not an uncertainty. Default threshold: 0.7.
  • camera_pan|tilt|rotation [deg], camera_scale, camera_sigma0 (residual of the reference-network fit).
  • inlier_{ch}, reproj_err_{ch}: contribution and residual of each reference.
  • Sharpness, FWHM, Dominance, Peak Intensity, Flux, SNR: in the "advanced" export of recent cameras only (see below); definitions: quality-metrics.md.

Exports received (PS des Coudres, D-045)

Two other formats, observed on the data (not documented in the FAQ):

  • "advanced" (<Station>_advanced_<start>_<end>.csv), the source of the analyses: one row per sensor and per measurement, at the native rate (15 min, 10 min depending on the station), time_utc in explicit UTC.
    • sensor_name, pattern_type (global_ref for a compensation reference; ref for a local reference, treated as a target, outside the compensation, according to the station manual and without reproj_err, seen on NORDEND), x / y [px], error_value, error_threshold (specific to each sensor: 0.3 to 0.7);
    • x / y are not the centroid of the spot in the image (NORDEND, 2026-10-16): by day (12:30 UTC, seven days), centroid − (x, y) is constant per sensor and differs from one sensor to another (PR17 −2.5 / −0.5 px, PR18 −3.1 / +1.6, PR16 −5.8 / −0.1, CTR02 −1.4 / −2.4, CTR04 −1.0 / −1.4). Centroid weighted above the median of a ±20 px frame, on a ±8 px window. At night, the spot is saturated and the offset changes (PR17 −0.7 to −1.3 px in x). Hypothesis: x, y designate the position of the reference pattern (station manual), not the spot itself.
    • relative_x / relative_y (presumably rx / ry), corr_x / corr_y (presumably rch / rcv, but not in mm, see below);
    • reproj_err and inlier: references only; sigma0: one value per measurement, repeated on each row; no camera_pan|tilt|rotation|scale.
    • peak, flux, sharpness, fwhm, dominance, snr: the image quality of each target, computed by the GPU of recent cameras (run.md); "Empty for most devices today" (handoff G, docs/aimsight/AIMsight_handoff_G_site_health.md). Filled on LENZSPITZE and NADELHORN, empty elsewhere (pumping of October 2026); inventory.py says, on a batch, which columns carry values. For older cameras, ~/optical_emulator recomputes them from the DIFF images in quality/ (run.md), with stacking, exposure, gain, rotation and the image flag, to be joined on time_utc and sensor_name. Definitions and reading: quality-metrics.md. Flux, SNR and sharpness relate to the observability of a target in the image, to be separated from the health of the reference network (AIMsight_agentic_support_project_context.md, §5.5 and §5.6).
    • A rejected measurement (error_value > error_threshold) keeps its row and its error_value; corr_x / corr_y are empty, not interpolated. "Rejected" is a judgment by AIMsight, not a sorting by the camera: the camera delivers all its measurements, and the platform of a client that integrates the data receives them and can display them (the user, 2026-10-28).
  • LENZSPITZE, relative x / y (2026-11-04): x / y there are the offset from the pattern's reference position (medians ~0 px), relative_x / relative_y are equal to corr_x / corr_y, pattern_type is empty. Provisional conversion, for this station only: ~/aimsight-data/extraction/lenzspitze_absolute.py rewrites data/LENZSPITZE/displacement/ in image px (pattern center from lentzpitze_patterns.json + the measured offset +330.5 / +15.8 px between the JSON frame and the IRON images + x / y) and fills pattern_type. To rerun after a re-pump. Limits: 1023 and 8019 have no pattern in the JSON, their x / y are emptied (8019 classed global_ref, by its reproj_err); relative_x in px is not reconstructed. To fix in due course: the frame of positions on the pumping side, and visibility.py, thermal_displacement.py, categories.py, which test pattern_type directly instead of data.is_reference (empty, they see no reference).
  • Camera movements (camera/<Station>_camera_<YYYYMMDD>.csv, pumping only, absent from the exports received): the camera pose at each registration, time_utc in UTC, median_|min_|max_ of pan, tilt, rotation [deg], scale, sigma0 at the minute; one row per measurement (min = max), at the instants of the displacements. A measurement instant without a row: the camera was not registered (NORDEND: 101 instants out of 6,071, of which 49 on 29 and 30/07). Orders of magnitude: pan, tilt of a few hundredths of a degree, scale within 10⁻³ of 1; differences of several degrees on NORDEND (pan up to 3.1°, tilt −2.8 to 4.0°), not explained. Sign: a positive tilt means the camera is nose-diving (the expert, 2026-11-03, BREITHORN: the tilt rises all October while the camera tilts). Read by overview.py and inventory.py (D-073).
  • Hourly (<Station>_<start>_to_<end>_1hour.csv): one row per hour, targets only. Per target: horizontal_displacement, vertical_displacement, their _min / _max, _error, _count_val.
    • timestamp without time zone: Swiss time (UTC+2 in October), at the start of the hour. Verified: _error = mean of the error_value of the hour, to within 0.0006 (median).
    • count_val counts the measurements of the hour, rejected ones included.
  • Unit of corr_x / corr_y: horizontal_displacement = factor × hourly mean of corr_x + constant offset (likewise vertical and corr_y, correlation ≥ 0.99). The factor depends on the pattern: target05 0.61, target 1.6, target02 4.3, target03 6.85, target04 7.9. If the hourly is in mm (FAQ), corr_x / corr_y are not. According to the user (2026-10-16), they are surely in px, the factor then being mm per px. This is compatible with NORDEND: at the jump of PR17 (08/10 02:30), corr_y drops by about 0.15, and relative_y (in px) by 0.26 px against 0.08 px for the other sensors; over the window, corr of PR17 ≈ 0.8 × (relative − mean of the relative of the global references), but a mean ignores the rotation and scale of the compensation. To confirm. The factor depends on the station: on NORDEND, vertical_displacement of PR17 = 55.5 × hourly mean of corr_y (r = 0.994, 244 hours), i.e. about 9 mm for its jump of 0.15.

Causes to tell apart for a displacement anomaly:

  • real movement of the structure;
  • camera movement;
  • instability of the compensation (Barcelona case);
  • local degradation of a target;
  • parallax or unsuitable model.

The authoritative reference is AIMsight_reference_quality_event_explainer_roadmap.md (AIMsight documentation, stored in Support-Agent, docs/aimsight/). The non-negotiable rules that relate to it:

  • build nothing on a binary inlier: RANSAC will be replaced by a weighted estimator; use continuous weights, N_eff, residuals, influence;
  • sigma0 alone and the number of references are never sufficient criteria;
  • do not confuse the image quality of a target with the quality of the reference network, nor a small residual with a well-constrained transformation;
  • do not confuse common-mode movement with structural movement, nor coherent references with physically fixed references.