maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

51 lines
3.2 KiB
Markdown

# WILDSTRUBEL: one shifted measurement between two outages, 20 to 31 October
You asked me to requalify the labels of this range under the new rules, where only what stands out from the noise of the corrected curves is labelled.
## In short
Both labels hold and are kept as they are. Over the whole range the station gives only one measurement, on 31/10 at 20:15. That measurement should not be trusted: it is shifted by a few mm because the camera tilted. No movement of the structure is seen. Before and after that measurement, there are no curves at all.
## Requalification
Kept 2, rewritten 0, removed 0.
- WILDSTRUBEL-200: kept. The 31/10 20:15 measurement is far above the noise. PB1_2 is 26 times its usual noise on the vertical curve, PB2_2 18 times, and PA_9 8 times on the horizontal curve.
- WILDSTRUBEL-201: kept. After 20:15 no sensor is measured at all, so the station delivers nothing.
## What happened
**The station is silent, before and after 31/10 20:15 (confirmed).** No displacement measurement arrives from 15/10 until 31/10 20:15. The station sends its system data and daytime images again from the evening of 30/10, but it still does not measure. After the single measurement of 20:15 it goes silent again, until 13/11. The voltage is normal, so this is not a lack of energy. The cause is not known.
**The one measurement of 31/10 is shifted, because the camera tilted (likely).** Compared with early October, the whole image has shifted, mostly vertically, because the camera tilted down and turned slightly. The targets keep the same positions relative to each other, and the correction removes most of the shift, but not all of it:
- PB1_2 (14 m away) and PB2_2 (17 m) sit about 3 to 4 mm higher on the vertical curve;
- PB_5 (23 m) sits about 1 mm higher;
- PA_9 (39 m) is shifted by about 5 mm on the horizontal curve.
The reference R2 is no longer found, and the correction runs on the other five references. The measurements of 13 and 15 November, after this range, keep the same shifted levels.
There is no weather station data for WILDSTRUBEL.
![Thumbnails of PB1_2, PB2_2, PA_9, R2, R1 on 09/10 and 31/10](thumbnails_0910_3110.png)
On 31/10, every frame has moved together with the camera, by a few pixels. R2's frame has jumped much further, and its spot is no longer at the centre.
## What to do
- Check with the operator why the station stops measuring for long periods while it is powered.
- Check the camera mount, which has tilted since early October.
- Look at R2 on site: it is lost from 31/10 onward.
## Not established
- Why the station does not measure while it is powered and communicating. The station's logs would settle it.
- Whether R2 moved or is just hidden. A daytime image of its spot would settle it.
- Whether the shift of 31/10 is only the camera or also a small movement of the structure. Daytime measurements, read against the references once R2 is back, would settle it.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 2026-10-31 20:00 | 2026-10-31 20:30 | Displacement | PB1_2, PB2_2, PA_9, PB_5; R2 lost | single measurement after the outage, shifted a few mm by a camera tilt |
| 2026-10-31 20:15 | 2026-11-01 00:00 | No data | all | station silent again until the end of the range |