# Requalification of the long labels: CLARIDEN
- **CLARIDEN-1** (Target issue, P-300-B, 01/10 → 01/11): **kept** as is. P-300-B is rejected at 4070 of the 4070 measurement instants present in the range (`inventory.py --start 2026-10-01T00:00Z --end 2026-11-01T00:00Z`; 6371 of 10137 over the whole period, since 29/09). A target rejected almost always: Target issue.
- **CLARIDEN-14** (Displacement, 06/10 22:00 → 11/10 06:00): **corrected** (description). The drift is beyond the threshold: `ranges.py --k 5` from 05/10 10:30 to 15/10 22:50, the level taken outside the label: D-301-C corr_x out of level up to −19.5 noises (−0.22 px, about −1.1 mm) until 08/10 09:20 before it rises to its later level; D-303-B corr_y up to −15.6 noises (about −0.44 mm) until 08/10 08:40; D-304-C corr_x −9.0, D-303-C corr_y −7.1, D-306-B corr_x +6.4 noises. Bounds and family hold. Correction applied (found by the analyst of the 01/10–11/10 period): "No camera movement" is wrong, the camera tilt drifts over these days and D-303-B, D-303-C, D-304-C, D-301-C follow it (hourly r −0.86 to −0.95, `CLARIDEN_2026-10-01T0000_2026-10-11T0000/analysis.md`); the conclusion becomes "camera to monitor". Review removed.
Sources read: `tools/GUIDE.md`, `tools/DATA.md`, `labeling/families.md`, `labeling/labeling-rules.md`, `labeling/reading-rules.md`, `labeling/stations.md`, `input.jsonl`, the analyses of the three CLARIDEN periods (lines on CLARIDEN-1 and CLARIDEN-14). Commands: `inventory.py` (month, `work/inv_month.txt`), `ranges.py` (corr and corr_mm, 5 targets, `--outside` the label).