aimsight-labeling/auto/analyses/CLARIDEN_2026-10-11T0000_2026-10-20T0400/labels.jsonl
T
maximeandClaude Opus 5.5 ddb17c2189 auto: labels requalified under the 5-noise rules (only what stands out from the noise): 32 analyses refined, the 6 paused periods verified, the long labels requalified with the fixes the period analysts found; 1153 -> 961 labels
- 32 analyses: each label kept, rewritten or removed by its analyst (section Requalification of the report; mm magnitudes where the targets have them)
- SNCF01 x3, WILDSTRUBEL 2026-09-01 -> 2026-10-06 x3: verified from their existing labels under the new rules
- long labels (no analysis): auto/analyses/long-labels/<STATION>/; NORDEND-169 and -195 run to 07/11, so NORDEND-283 and -284 (their continuation) are removed
- reading-rules.md, stations.md: the citations of removed or rewritten labels point to their successor, or to [expert]

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-17 23:58:00 +01:00

12 lines
9.2 KiB
JSON

{"start": "2026-10-11T06:00Z", "end": "2026-10-16T12:00Z", "family": "Displacement", "description": "The targets of row C slowly come back after their drift of the 6th to the 11th: D-301-C goes back down horizontally from the 11th to the 15th, D-304-C and D-303-C go back down vertically from the 12th until the first measurements after the gap of the night of the 15th to the 16th, then stay at that level until the 17th: the return is over. Their later movements are not part of it: the dip of the 18th and 19th follows the slow tilting of the camera and comes back at its jump of the 20th (both labeled separately). These movements do not follow the slight straightening of the camera of the 11th to the 13th either, which leaves only a remainder within the noise on the curves: they continue while the camera is still. Nothing in front of the targets on the image of the 13th. The housing temperature stays almost constant over these days: no link with it. This is the return of the drift of the 6th to the 11th, labeled separately. Cause not established, in a tunnel under construction: a movement of these targets is not excluded. To be checked against the other measurements of the site; monitor this row."}
{"start": "2026-10-11T08:50Z", "end": "2026-10-11T09:10Z", "family": "Displacement", "description": "For one measurement, the corrected vertical curves of many targets drop together, then come back at the next one. D-304-A, D-301-A, D-303-A and D-302_A drop the most; D-301-C, D-302-B and PR_BG (same prism), P-299-B, P-301-B and P-299-A drop less. At that measurement, the whole scene shifts slightly in the image and the camera pose jumps (rotation, tilt), but the reference D-302-C does not follow the other references: the compensation is skewed for one measurement. The recognition error does not move. The image of that instant shows nothing in front of the targets. Cause not established; points to ignore, not a movement of the structure."}
{"start": "2026-10-15T22:50Z", "end": "2026-10-16T10:30Z", "family": "No data", "description": "No measurement or image for almost twelve hours, on the night of 15 to 16, and no station metric. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. In addition, at CLARIDEN, the station restarts on its battery: the voltage stays well below its usual level, without charge, until early afternoon, then charging resumes; its power supply was also missing that night. The curves are missing over the range; check the site power supply if it repeats."}
{"start": "2026-10-16T14:20Z", "end": "2026-10-16T14:40Z", "family": "No data", "description": "One measurement is missing, for all sensors, a few hours after the resumption of the 16th: the curves have a short gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-17T16:00Z", "end": "2026-10-20T00:30Z", "family": "Displacement", "description": "From the 17th to the 19th, the camera slowly tilts the other way: its tilt goes down, more and more after the restart that follows the outage of the 18th; it partly comes back during the 19th, then suddenly jumps back on the 20th (labeled separately). The raw positions of all sensors, references included, move together vertically in the image with it. The compensation does not render this movement evenly. The corrected vertical curves of D-302-B and PR_BG (same prism) rise. Those of D-303-B, D-304-B, P-301-B, D-306-B, D-303-C and D-304-C go down, and D-301-C rises a little horizontally. They follow the tilt step by step, come back partly with it on the 19th, and return at once at the camera jump of the 20th. The recognition error stays at its level, and the image of the 19th shows nothing in front of the targets. The housing temperature drops a little on the 18th and is low at the restart after the outage; but the tilt keeps going down after the housing has warmed again, and it does not come back at equal temperature: link not established. This is not a movement of the structure but the remainder of an incomplete compensation of the camera movement; the camera is to be monitored."}
{"start": "2026-10-18T06:30Z", "end": "2026-10-18T06:50Z", "family": "Displacement", "description": "For one measurement, the corrected horizontal curves of the targets of row A (D-304-A, D-302_A, D-303-A, D-300-A, P-298-A, D-301-A) and of D-302-B and PR_BG (same prism) jump together, then come back at the next one. The raw positions of the targets do not move; the references PR-291, PR-293 and PR-295 shift slightly horizontally against them, and the camera pose jumps (pan, scale): the compensation is skewed for one measurement. The recognition error stays at its level. There is no image at that instant; the image of the next hour shows work lights at the far end of the tunnel and nothing in front of the targets. Cause not established; points to ignore, not a movement of the structure."}
{"start": "2026-10-18T08:50Z", "end": "2026-10-18T09:30Z", "family": "Visibility", "description": "For three measurements, the corrected curves of many targets make a bump that comes back: first the targets of row A (D-300-A, D-301-A, D-302_A, D-303-A, D-304-A, P-298-A) rise vertically; over the next two measurements, the recognition error of most targets and of the references PR-293 and PR-295 rises, D-302-B and PR_BG (same prism) rise strongly vertically, D-301-C goes down strongly horizontally, and P-301-B and D-303-B move horizontally. All come back at the following measurement. The camera pose jumps at the same time (tilt, scale), and the housing temperature drops. The image of the first measurement shows nothing in front of the targets. The signature is that of the other view obstruction episodes at the station: the error rises on most sensors, and the edges are sharp. Reduced visibility is deduced from it; the cause is not seen. Points to ignore."}
{"start": "2026-10-18T13:50Z", "end": "2026-10-18T23:30Z", "family": "No data", "description": "No measurement or image for almost ten hours, nor station metric. On resumption, the battery is depleted and the voltage low, then they rise: signature of a power cut. The curves are missing over the range; check the power supply if it repeats."}
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T10:10Z", "family": "No data", "description": "Four measurements are missing within one hour, for all sensors, between isolated measurements: the curves have gaps; normal voltage around them. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station."}
{"start": "2026-10-19T20:40Z", "end": "2026-10-19T21:30Z", "family": "No data", "description": "Three measurements are missing in less than an hour, for all sensors: the curves have a gap; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (FLORIDA, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00."}
{"start": "2026-10-20T00:10Z", "end": "2026-10-20T00:40Z", "family": "Displacement", "description": "On the 20th, over two measurements, the whole scene, references included, suddenly shifts in the image, mostly vertically: the camera has moved (its tilt jumps). The compensation absorbs most of it, but the corrected curves of several targets jump. Vertically, D-303-C, D-304-C, D-304-B, D-303-B and P-301-B go back up to the level they had before the slow tilting of the camera of the 17th to the 19th (labeled separately): this jump erases its remainder. D-306-B jumps up clearly, beyond its earlier level, and stays there. D-302-B and PR_BG (same prism) jump horizontally and stay there. The recognition error of D-302-B and D-303-B changes level at the same moment. Work lights are visible at the far end of the tunnel on the images of the hour before and the hour after; nothing is in front of the targets. The cause of the camera movement is not established. The lasting jumps of D-306-B and D-302-B are not an established movement of the structure: to be checked; the camera is to be monitored."}