{"start": "2026-10-15T20:00Z", "end": "2026-10-16T12:00Z", "family": "No data", "description": "No measurement for any sensor in the night of 15 to 16 October: three measurements are missing, all the curves are cut, then everything resumes at the same level. The station metrics are also missing over these hours (temperatures, voltage, synchronization); the voltage is normal just before and just after, the battery full: no sign of a power cut. The same gap affects the two other stations of the building (BREITHORN, NEBRASKA, in the same building according to the expert), but also all the other stations. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The cause is therefore not specific to the building. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
|
|
{"start": "2026-10-17T12:00Z", "end": "2026-10-18T08:00Z", "family": "Perturbation", "description": "All the targets become agitated together for three measurements: the corr_x goes down at 16:00 on 17 October, the corr_y plunges at 20:00, then corr_x and corr_y rise above their level on 18 October at 04:00, and everything returns. The camera pose computed on REF42 and REFG43N swings back and forth (tilt, rotation) without the raw positions of the targets moving clearly, and the gap between the two references changes a little: it is the two-reference compensation that carries this gap over to all the targets. The temperatures then drop in steps, but without a brief variation at the time of these deviations. Cause not established, nothing on the images. For the customer: this is not a movement of the structure, the points of this range are to be ignored.", "review": "2026-11-17"}
|
|
{"start": "2026-10-19T00:00Z", "end": "2026-10-19T12:00Z", "family": "Thermal displacement", "description": "On 19 October in the morning, the corr_y of all the targets plunges together for two measurements, the corr_x too at the second, then everything returns at noon. The camera housing temperature makes a brief drop at the same moment, at the end of the night, and the camera moves: it nods forward, rotates, its scale drops, the raw positions of all the targets and of the two references slide almost together; the targets do not move relative to each other. The compensation on two references only, REF42 and REFG43N, carries their small gap relative to the targets over to all the targets. The first affected measurement slightly precedes the temperature drop. Cause deduced from the curves and the camera housing temperature; nothing in front of the targets on the 08:00 image. For the customer: this is not a movement of the structure, nothing to do.", "review": "2026-11-17"}
|