57 lines
4.1 KiB
Markdown
57 lines
4.1 KiB
Markdown
# Station Guide — Working with Conventional Image Features
|
|||
|
|
|
||
|
|
When reflectors are unavailable or difficult to install, sufficiently contrasted and stable visual
|
||
|
|
features may also be tracked. If the installed software provides the Work on IRON images option,
|
||
|
|
enable it to work with conventional images rather than the contrast-enhanced reflector
|
||
|
|
representation. Verify that the selected texture remains visible and stable under all expected
|
||
|
|
measurement conditions.
|
||
|
|
Once a zone has been drawn, a new row appears in the “Marker Configuration” table.
|
||
|
|
Define the marker parameters in the “Marker Configuration” table:
|
||
|
|
• Name: name of the position marker, that is, the name of the measurement channel
|
||
|
|
• Type: assigns the marker to a group or type. Reference targets are considered fixed points,
|
||
|
|
while markers in “Target Group(s)” are tracked. Proper selection of reference targets is
|
||
|
|
essential because they are used to compensate for camera motion.
|
||
|
|
• Global reference: a point considered fixed in the monitored scene. Global-reference points
|
||
|
|
are used to estimate and compensate for movement of the monitoring station itself.
|
||
|
|
• Local reference: identifies a measurement point as belonging to the local-reference group.
|
||
|
|
This designation is used for classification and display purposes only. Unlike a Global
|
||
|
|
reference, a local reference is not treated as a fixed point and is not used to compensate for
|
||
|
|
movements of the monitoring station. No additional processing is applied; local references
|
||
|
|
are handled in the same way as other measurement-point groups.
|
||
|
|
• Error Threshold (optional): threshold above which a measurement is considered invalid.
|
||
|
|
This is used to detect obstructions, for example when a marker is hidden by a vehicle or
|
||
|
|
vegetation. By default, the error threshold is 0.7.
|
||
|
|
• Pattern Size: adjusts the size of the image-processing area around the marker
|
||
|
|
• Resolution (optional): processing resolution, expressed as a fraction of a pixel. The default
|
||
|
|
value is 100, corresponding to one hundredth of a pixel. Lower values reduce processing
|
||
|
|
time.
|
||
|
|
• Distance: straight-line distance in millimeters between the front of the camera and the
|
||
|
|
marker. This is used to calculate the correct pixel-to-distance conversion factor.
|
||
|
|
An error in the entered distance produces a proportional scale error. For example, a coarse
|
||
|
|
distance error of 1%—such as entering 99 m or 101 m instead of 100 m—produces an error of
|
||
|
|
approximately 0.1 mm on a measured displacement of 10 mm.
|
||
|
|
• Reference date: records the time at which the reference pattern defining the zero position
|
||
|
|
was set
|
||
|
|
To adjust the position of the marker area, first select it by clicking its border. You can then drag
|
||
|
|
its corners to reshape it or drag inside the area to move it. It is generally best to keep the marker
|
||
|
|
centered within the target region.
|
||
|
|
The “Recapture” button allows you to take a new image and verify that the marker zones are
|
||
|
|
correctly defined.
|
||
|
|
Once the settings have been established, save the pattern configuration by clicking “Save
|
||
|
|
Configuration”. The reference patterns are then extracted from the image currently displayed.
|
||
|
|
This image becomes the zero for each channel, and subsequent displacements are calculated
|
||
|
|
relative to the positions saved at that moment. To redefine the zero, display or recapture an
|
||
|
|
appropriate new image, verify all zones and parameters, and save the configuration again.
|
||
|
|
The “Store Locally” toggle must be enabled if the system is to keep measurements in onboard
|
||
|
|
memory.
|
||
|
|
If the system has internet access through either Ethernet or the onboard 4G module, it can also
|
||
|
|
be configured to forward measurements to the AIMsight database by enabling “Send to Server”.
|
||
|
|
The “Send to Monitoring” option must be enabled to transmit measurements in real time to the
|
||
|
|
monitoring platform. When activated, the system continuously sends data to the remote
|
||
|
|
supervision interface, allowing live tracking and analysis.
|
||
|
|
The “Send to FTP Server” option must be enabled to upload the measurements automatically to
|
||
|
|
an external FTP server. This allows the data to be archived and accessed later for analysis or
|
||
|
|
backup purposes.
|
||
|
|
Target Configuration
|
||
|
|
|
||
|
|
Source : AIMsight Station Guide, rév. 1.5
|