@@ -0,0 +1,27 @@
|
||||
# Station Guide — Camera Management Panel
|
||||
|
||||
You can display the “Camera Management” side panel from any page by clicking the camera
|
||||
icon in the top-right corner of the interface.
|
||||
The camera button and the top navigation bar change color to indicate the acquisition status:
|
||||
• grey when idle
|
||||
• green during an acquisition
|
||||
Live View images are not considered an acquisition.
|
||||
1. Live processing toggle: enables image acquisition at the specified frame rate and the
|
||||
processing of the raw images into displacement measurements
|
||||
2. Framerate slider: sets the camera acquisition frame rate
|
||||
3. FPS Production: displays the current image-acquisition rate
|
||||
4. FPS Processing: displays the processing rate in each thread. For continuous monitoring,
|
||||
verify that processing is fast enough to keep up with image capture.
|
||||
5. Processing Queue: displays the number of image blocks waiting to be processed. For
|
||||
continuous monitoring, the frame rate should be kept low enough for the queue to remain
|
||||
close to empty.
|
||||
6. Continuous acquisition mode: can be enabled for maximum frame-rate stability, at the
|
||||
expense of battery life
|
||||
7. RTSP Stream: streams the live video feed on port 8554
|
||||
NOTE
|
||||
For short burst-mode measurements, the system can capture data at a much higher frame
|
||||
rate than the real-time processing rate. In such cases, the maximum measurement duration
|
||||
without data loss is limited by the queue size and is typically on the order of 60 seconds.
|
||||
The actual duration should always be verified with the final settings.
|
||||
|
||||
Source : AIMsight Station Guide, rév. 1.5
|
||||