Base de connaissances reprise de Support-AI : corpus, import, instructions, tests
Ajoute aussi WEISSHORN et MISSISSIPPI au test du corpus, et un message clair quand LibreDesk est injoignable. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
3a6e693d6d
commit
cce2e039ed
130 files changed
+2784
No files matched your search
@@ -0,0 +1,32 @@
|
||||
# Station Guide — Charging
|
||||
|
||||
CAUTION
|
||||
The system tolerates a maximum input voltage of 26 V on both the power-supply connector
|
||||
and the optional passive PoE input. Never connect a standard IEEE PoE source (802.3af,
|
||||
802.3at or 802.3bt), as the standard PoE voltages of 48 V and above may damage the
|
||||
charge controller.
|
||||
CAUTION
|
||||
The centre pin of the barrel connector is positive. If you are not using an AIMsight-supplied
|
||||
power solution, always verify the connector polarity before connection, especially when
|
||||
using third-party adapters such solar panels with MC4 connectors or adapters.
|
||||
For mains-powered operation, connect the supplied power supply to an electrical outlet, then
|
||||
connect it to the camera. This operating mode is recommended for charging the battery between
|
||||
mobile deployments or when power is available at the monitoring site. In this configuration, the
|
||||
battery remains connected and acts as an internal backup power source (UPS) in case of a
|
||||
temporary power interruption.
|
||||
For autonomous field operation, the camera can be connected to a solar panel. We recommend
|
||||
using a standard 12 V solar panel; in most cases, a generic 100 W panel provides sufficient
|
||||
charging capacity. Install the panel in a location with good sun exposure and orient it
|
||||
appropriately for the site conditions.
|
||||
The battery charges automatically whenever a suitable external power source is connected.
|
||||
Charging performance depends on the available input power, battery state of charge, and
|
||||
ambient conditions. For reliable operation, ensure that the external power source remains within
|
||||
the specified voltage range and is capable of supplying adequate current.
|
||||
NOTE
|
||||
After a deep discharge (battery voltage below 12 V), the camera may not restart immediately.
|
||||
To prevent repeated restart attempts caused by an insufficient charge level, the system
|
||||
remains off until the battery voltage reaches approximately 12.6 V before powering up again.
|
||||
While charging, verify that the charge-status LED is red. Once the battery has recovered to
|
||||
the required voltage, the system will start automatically, provided that it is switched on.
|
||||
|
||||
Source : AIMsight Station Guide, rév. 1.5
|
||||
Reference in new issue
Block a user