# Station Guide — Live Plot
|
||||
|
||||
The Live Plot tab allows you to view data acquisition in real time by clicking the record button in
|
||||
the upper-right corner.
|
||||
The following graph types are available:
|
||||
• Relative Horizontal: relative horizontal displacement of the marker, converted into
|
||||
millimeters
|
||||
• Relative Vertical: relative vertical displacement of the marker, converted into millimeters
|
||||
• Raw Horizontal: raw horizontal position of the target in the image, in pixels
|
||||
• Raw Vertical: raw vertical position of the target in the image, in pixels
|
||||
• Error value: error metric comparing the current image of the target to the reference image
|
||||
in order to detect obstructions
|
||||
The “Time Range” setting determines the time window queried and displayed in the chart.
|
||||
Although it can be changed during an acquisition, it is generally better to set it at the beginning.
|
||||
In the upper-left corner, the plot-options menu gives access to three groups of settings:
|
||||
• plot updates
|
||||
• plot scale
|
||||
• obstruction handling
|
||||
These options allow you to override the error threshold and use features such as auto period,
|
||||
lock y, and highlight + filter/hide to visualize or suppress high-error periods.
|
||||
Example of a real-time acquisition showing target signals together with station motion
|
||||
Example of the same acquisition after compensation for station motion
|
||||
These figures show a live acquisition. The first plot includes both target signals and camera
|
||||
motion, which can distort the actual measurements. The second plot displays only the corrected
|
||||
target movements, with camera motion removed. This option can be configured in Data
|
||||
Exploration (see page 12)
|
||||
|
||||
Source : AIMsight Station Guide, rév. 1.5
|
||||