- base_connaissances/ → snippets/ (corpus/ → textes/, instructions.md → consignes_redaction.md, decoupage.py → fichiers.py, importer.py → envoyer.py) ; python3 -m snippets.envoyer. - instance-de-test/ : 1_demarrer.sh, 2_creer_boite_et_cle.py, 3_brancher_ia.py, 4_essayer_brouillons.py, voir_empreintes.sh, connexion_admin.py. - ollama/verifier.py → ollama/verifier_ollama.py ; tests, tâches VS Code et docs alignés. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
20 lines
1.2 KiB
Markdown
20 lines
1.2 KiB
Markdown
# Station Guide — Pattern Creation Page
|
|
|
|
This page allows you to configure image acquisition parameters and image processing, including
|
|
the definition of the markers tracked by the camera.
|
|
The Preset bar at the top of the page allows several target configurations, each with its own
|
|
acquisition settings and processing zones, to be stored in addition to the main or default
|
|
configuration.
|
|
Defining a target establishes the reference pattern that the system searches for in each
|
|
subsequent image to calculate target motion. In the local web interface, the reference pattern is
|
|
extracted from the image currently displayed when Save Configuration is clicked. That image
|
|
defines the zero position from which all subsequent relative or differential displacements are
|
|
calculated. The corresponding date and time are recorded as the Reference date in the
|
|
measurement-channel definition.
|
|
Before saving, verify that the displayed image is representative, that all targets are clearly visible,
|
|
and that no temporary object obscures a tracking zone. Saving the configuration again extracts
|
|
new reference patterns from the currently displayed image and therefore redefines the
|
|
displacement zero.
|
|
|
|
Source : AIMsight Station Guide, rév. 1.5
|