- base_connaissances/ → snippets/ (corpus/ → textes/, instructions.md → consignes_redaction.md, decoupage.py → fichiers.py, importer.py → envoyer.py) ; python3 -m snippets.envoyer. - instance-de-test/ : 1_demarrer.sh, 2_creer_boite_et_cle.py, 3_brancher_ia.py, 4_essayer_brouillons.py, voir_empreintes.sh, connexion_admin.py. - ollama/verifier.py → ollama/verifier_ollama.py ; tests, tâches VS Code et docs alignés. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
22 lines
1.6 KiB
Markdown
22 lines
1.6 KiB
Markdown
# (AIMsight Cloud — optional service) How can I apply a target configuration from a historical image?
|
|
|
|
The general Pattern Configuration workflow is shared by the local station interface and AIMsight
|
|
Cloud. The Cloud interface additionally allows patterns to be defined from a stored image and
|
|
the affected measurements to be reprocessed.
|
|
After selecting the image at the required date and configuring the targets, the Actions button and
|
|
Update Strategy dropdown determine how the new reference is applied:
|
|
• Reinitialize — Uses the selected image and configuration as a new reference and restarts
|
|
the corresponding displacement values from zero. This is typically used when reconfiguring
|
|
all targets, for example after a significant movement or repositioning of the camera station.
|
|
• Reinitialize with motion compensation — Preserves the reference network and cameramotion correction while reinitializing an individual target. A typical case is a prism that was
|
|
accidentally moved and then placed back at a slightly different position.
|
|
• Continuous — Applies the updated pattern or reference while preserving continuity of the
|
|
existing measurement trace. The displacement curve therefore does not return to zero
|
|
when the new reference is introduced. This is useful when a pattern must be updated or
|
|
refined without creating a discontinuity in the history.
|
|
Before applying the action, verify the date of the selected image, the target zones, the reference
|
|
network, and the intended result. The selected strategy determines both the measurement zero
|
|
and the continuity of the reprocessed data.
|
|
|
|
Source : AIMsight FAQ, rév. 1.5
|