- base_connaissances/ → snippets/ (corpus/ → textes/, instructions.md → consignes_redaction.md, decoupage.py → fichiers.py, importer.py → envoyer.py) ; python3 -m snippets.envoyer. - instance-de-test/ : 1_demarrer.sh, 2_creer_boite_et_cle.py, 3_brancher_ia.py, 4_essayer_brouillons.py, voir_empreintes.sh, connexion_admin.py. - ollama/verifier.py → ollama/verifier_ollama.py ; tests, tâches VS Code et docs alignés. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
22 lines
1.1 KiB
Markdown
22 lines
1.1 KiB
Markdown
# The camera is online, but I am not receiving data. What should I check?
|
||
|
||
An online camera does not necessarily mean that measurements are being acquired or exported
|
||
correctly. Acquisition and data transfer should be checked separately.
|
||
First verify measurement acquisition:
|
||
• Is the required acquisition schedule enabled?
|
||
• Has the scheduled acquisition time been reached?
|
||
• Can a measurement be triggered manually?
|
||
• Are valid target measurements being produced?
|
||
• Are the expected measurements visible in the local interface or Data Exploration tools?
|
||
Then verify data transfer:
|
||
• Is the required FTP, optional AIMsight Cloud, or other export destination configured?
|
||
• Is the destination server reachable?
|
||
• Are the hostname, address, port, and path correct?
|
||
• Are authentication credentials valid?
|
||
• Is the expected export format enabled?
|
||
• Is the station’s Internet connection operational if the destination is remote?
|
||
If data are available locally but do not reach the external destination, the problem is most likely
|
||
related to communication or export configuration rather than measurement acquisition.
|
||
|
||
Source : AIMsight FAQ, rév. 1.5
|