# My measurements suddenly become noisy or invalid. What should I check?
Useful checks include:
• whether the target remains visible and inside its processing area;
• water, condensation, dirt, or contamination on the target or camera window;
• partial or complete target obstruction;
• significant changes in illumination;
• atmospheric turbulence or heat shimmer;
• excessive camera movement; and
• sigma0 if reference targets are being used.
The diagnostic signals can help narrow down the likely cause:
• An increasing Error Value indicates that the target image no longer matches its reference
reliably. This can result from obstruction, changed appearance, poor visibility, or incorrect
registration.
• Decreasing Sharpness together with increasing FWHM suggests that the target image is
becoming more diffuse, for example because of defocus, vibration, motion blur, or
atmospheric turbulence.
• Decreasing Peak Intensity, Flux, and SNR suggests reduced illumination, partial
obstruction, contamination, reflector misalignment, or generally poorer target visibility.
• Increasing Dominance indicates that another bright feature is competing with the tracked
reflector and that the risk of selecting the wrong image feature is increasing.
• Similar apparent movement across several targets, accompanied by a change in Camera
Movement, points toward movement or instability of the camera support.
• An increase in sigma0 indicates that the reference targets are becoming less consistent with
a single global camera movement and may indicate deformation of the reference network.
The corresponding camera image remains essential for confirming the interpretation. When
AIMsight Cloud and image archiving are enabled, the image associated with a selected
measurement or period can be opened directly from the history view. The image and the trends
in Error Value, Sharpness, FWHM, Dominance, Peak Intensity, Flux, SNR, Camera Movement,
and sigma0 together provide the most effective way to distinguish between:
• a visibility or target-recognition problem;
• optical degradation or atmospheric disturbance;
• camera instability;
• deformation of the reference network; and
• actual structural movement.
Source : AIMsight FAQ, rév. 1.5