Files
aimsight-optimizer/sessions/LENZSPITZE_2026-10-23T2355_2026-11-01T1140_20261118T1049Z/modification.md
T

13 KiB
Raw Blame History

Modification

Verdict: changed Changed: scripts/displacement.py, thresholds.md

Diagnosis

LENZSPITZE, 2026-10-23 → 2026-11-02 (UTC), one measurement every 5 min (31 targets, 8 references).

Family labelled found flagged wrongly
Displacement 0 0 2943 → 27 2943 → 27
No data 6 4 4 0
Obstruction 58 17 486 469
Perturbation 6 1 426 425
Thermal displacement 1469 1342 2611 1269
Visibility 1166 817 875 58
  • Extra, the largest defect: a Slow drift (Displacement, kept) on 1001 and 1010 covering the whole window read, 10-20 00:00 → 11-01 23:55, i.e. every instant of the range. There is no Displacement label on the range, and the report says no real movement of the structure is seen. Cause: the whole-window branch of displacement.drift (_whole) fires when the trend over the window reaches SIZE = 1 median daily amplitude. Here the trend is 1.0 amplitude (1001 corr_x, −0.08 px in 12 days) and 1.1 amplitudes (1010 corr_y, +0.05 px). The same mechanism shows up elsewhere: PR16 over the whole NORDEND window (1.0), and 1012/1016/1018 on the earlier LENZSPITZE range (1.0 to 1.9). None of these is labelled. The one labelled whole-window drift (WILDSTRUBEL-89, PB2_2) is 2.6 amplitudes.
  • Extra, Obstruction "Target obscured" on 9 distant sensors, 10-26 00:00 → 10-27 ~08:30. These overlap the mist nights LENZSPITZE-101 and -44 (Visibility) and the day LENZSPITZE-42 in between. Cause: target_issue counts 2 UTC days rejected ≥ 25 % (two mist nights in a row) as a target hidden for a few days. It does not tell a rejection shared by much of the scene apart from one specific to the target. → Not fixed.
  • Wrong family / missed, the short partial occultations (LENZSPITZE-89, 94, 49, 50, 59, 63, 109, 110, 111, 112, 113, 115; Obstruction): the detectors see a single-target "Sudden jump, back to normal" (Perturbation) or nothing. Only the flux of the hidden targets drops. Their error_value stays near its median (e.g. 1022 on 10-29 14:35: +3.9 MAD; 92H on 10-30 13:55: +6.2 MAD, under K_MAD) and they are not rejected, so visibility's Brief obstruction cannot see them. → Limits.
  • Correct, the passages of the even group (LENZSPITZE-39, 95, 102, 103, 104, 48, 54, 57, 60, 62, 65, 119, 67, 69): Brief obstruction at the right instant.
  • Wrong bounds, Thermal displacement (all daily labels, 36, 93, 97, 42, 45, 52, 56, 61, 114, 117): found 91 % but correct 51 %. The corrected-curve wave fails at station level: 8 of the 31 targets have a reproducible cycle (SHARE 0.5), and no target has a 24 h sine above R2_MIN, the best being 1007 at 0.29. The camera wave on x, y fails too. The fallback "Camera thermal movement" (common slides) then makes one block 10-20 10:30 → 10-30 13:05, bridging the nights (runs(..., DAY)). → Not fixed.
  • Missed, turbulence on 28 Oct (LENZSPITZE-55, Visibility, 0/37): every sensor is agitated ×1.9 to ×2.9 its calm, but the median error_value stays at ×0.9 of its calm, so heat_shimmer's error criterion rejects it. The families document says "the pose shaking without the error_value rising is not turbulence", yet the label says the error rises. → For the user to decide.
  • Missed, partial dimming (LENZSPITZE-37, 99, 107, Visibility, a few targets for half an hour): same blindness to flux as the occultations. → Limits.
  • Extra Perturbations (426 instants): single-target jumps that come back hours later (e.g. 1019 10-24 11:40 → 23:00, 101B 12:15 → 22:40) and fall just outside the detected Visibility episodes. MERGE then joins them into multi-hour "31 sensors" events. A return after hours is a Perturbation by design (ALASKA 2026-11-04, S5). The defect is in the short bounds of the visibility episodes around them. → Not fixed.
  • Wrong family, Lasting shift on one target during visibility episodes (10-25 11:25 1021, 10-26 07:00, 08:30, 10-27 09:25): 1 instant each, now the only 27 wrongly flagged Displacement instants. Small → Not fixed.
  • Partly found, Perturbation of 8012 (LENZSPITZE-105, 106, 108): the shift of the far reference passes to the targets below K_TOGETHER. Covered by Thermal only. Small → Not fixed.
  • No data LENZSPITZE-43 and -46 are correct. LENZSPITZE-58 (one missing measurement, 10-29 15:05-15:15) is missed: it is a hole of a single step (MISSING). Its 2 bound instants only.

What changed

  • S1 (f623b79), scripts/displacement.py: constant SIZE 1.0 → 2.0. A slow drift over the whole window must now reach twice the median daily amplitude. thresholds.md: the SIZE line updated.
  • S2 (c8fb838), pruning: the Kendall-tau condition (STEADY = 0.6) is removed from both the whole-window test and the pieces, along with its computations (tau in _whole, signs in _pieces). The docstring comment and the STEADY line of thresholds.md are removed.
  • S3 (466799f), pruning: constant DAYS = 5 removed. An axis needs at least two kept days (the minimum for a slope), and the n >= DAYS condition of the pieces is gone. Because a drift may not contain a day-to-day step larger than half of it, a drift still needs at least three days. The comment, the unused n and the DAYS line of thresholds.md are updated or removed.

Why

  • S1: a trend of one daily amplitude over a whole window is not a movement but the wander of a healthy target. At that threshold the whole-window branch flagged untouched targets of several stations as Displacement across the entire window. At two amplitudes the trend has to clearly exceed the daily swing, and the labelled whole-window drift is still found.
  • S2, S3: with the step condition and the size thresholds in place, the steadiness condition and the minimum day count removed nothing anywhere in the benchmark. Removing them is a simplification without a regression.

Checks

  • events: one line removed, 2026-10-20T00:00Z → 2026-11-01T23:55Z Displacement kept | Slow drift | 2 sensors. Nothing else changes, and no skipped line.
  • sensors: the line Displacement | Slow drift | 1001, 1010 removed.
  • range: Displacement correct 0/2943 → 0/27. Every other line is unchanged.
  • benchmark: see below. S2 and S3 leave every figure identical to S1.

Pruning

Rules of the slow drift (displacement.drift), each tried alone on a copy:

  • the Kendall-tau condition (STEADY), whole window and pieces: removed, S2 c8fb838 (no figure changes).
  • DAYS, the minimum day count: removed, S3 466799f (no figure changes).
  • the step condition of _whole: kept. Without it, CLARIDEN Displacement correct 42 → 35 % (713 instants) and Total correct 41 → 36 %.
  • the step condition of _pieces: kept. Without it, CLARIDEN correct 42 → 35 % and Total correct 41 → 30 %.
  • the whole-window branch: kept. Without it, WILDSTRUBEL Displacement found 94 → 0 % (499 instants) and Total found 98 → 87 %.
  • the pieces branch: kept. Without it, CLARIDEN found 100 → 0 % (1421 instants) and Total found 98 → 66 %.
  • HOURS, the day coverage: kept. Without it, Total Displacement correct 41 → 38 % (745 instants).
  • SIZE = PIECE (3.5, one constant less): kept. It gives WILDSTRUBEL found 94 → 0 % and Total found 98 → 87 %.
  • d and (non-zero drift) in _pieces: no figure changes, but kept. It is the only guard against a piece of zero drift on a constant series (amplitude 0), such as corrections stuck at zero. See "For the user to decide".

Before / after on the range

Events check, the only changed line:

< 2026-10-20T00:00Z → 2026-11-01T23:55Z Displacement         kept | Slow drift | 2 sensors | absorbed: Slow drift 10-20T00:00

Range score, before → after:

  • Displacement: found — → —; correct 0/2943 (0 %) → 0/27 (0 %)
  • No data: 4/6, 4/4 (unchanged)
  • Obstruction: 17/58, 17/486 (unchanged)
  • Perturbation: 1/6, 1/426 (unchanged)
  • Thermal displacement: 1342/1469, 1342/2611 (unchanged)
  • Visibility: 817/1166, 817/875 (unchanged)

Benchmark

           NORDEND      Displacement          found    100 →   0 %  (4 instants lost)
           Total        Displacement          correct   18 →  41 %

0 regression(s); complexity: 611 code lines, 48 constants → 606 code lines, 46 constants

The NORDEND drop (4 instants, below the regression thresholds) is not a loss of detection. The one-measurement Displacement labels NORDEND-94, -250, -276 and -309 were counted as found only because PR16's whole-window Slow drift (1.0 amplitude) covered the whole 3 months. That is an event on another sensor, which the per-instant score counts.

For the user to decide

  • S1 sets the whole-window drift at 2 daily amplitudes. Untouched targets at 1.0 to 1.9 amplitudes are no longer flagged: 1001, 1010, 1012, 1016, 1018 of LENZSPITZE and PR16 of NORDEND, with no label on any of them. WILDSTRUBEL's PA3_2 (1.9) and PA_9 (1.6) drop out too, but PB2_2 (2.6) still covers WILDSTRUBEL-89. If the user reads a steady 1-to-2-amplitude creep over weeks as a Displacement ("keep watching it"), 1.5 would keep 1016 and the two WILDSTRUBEL PA drifts.
  • LENZSPITZE-55 (LENZSPITZE, 10-28 11:00-14:05, Visibility, turbulence): the agitation is clear, but error_value does not rise against its calm. The detectors follow the families boundary ("the pose shaking without the error_value rising is not turbulence"), while the label calls it turbulence. Dropping the error criterion would need the user to change that boundary.
  • The d and guard of _pieces is kept despite no figure change: it guards against the degenerate case of constant curves.

Not fixed

  • Target obscured during two consecutive mist nights (10-26 → 10-27, 9 sensors, ~115 instants of LENZSPITZE-101 and 181 of -42 flagged Obstruction). Tried two fixes. Counting only rejections shared by fewer than half of the sensors gave 4 regressions (NIEDERHORN, NORDEND, Total Obstruction found and correct). MIN_DAYS 2 → 3 gave 3 regressions (NIEDERHORN, WILDSTRUBEL, Total found). Target obscured is worth 1085 found instants elsewhere.
  • Thermal displacement bounds on LENZSPITZE: the slide fallback bridges nights over 10 days. Narrowing its merge gap to 12 h or 6 h gave regressions (LENZSPITZE found 92 → 81/76 %, WYOMING 51 → 36/33 %, Total found −3/−4 points). Detecting a wave carried by a minority of targets (8/31 here) would change the station-level rule (SHARE, R2_MIN) for every station: not attempted in a small step.
  • Multi-hour Perturbation events around the visibility episodes (single-target jumps back after hours, outside the detected Visibility bounds).
  • Lasting shifts of one target inside visibility episodes (4 instants) and the 8012 reference shifts (LENZSPITZE-105, 106, 108): small.

Limits

  • LENZSPITZE-89, 94, 49, 50, 59, 63, 109, 110, 111, 112, 113, 115 (Obstruction, 10-23 13:30 to 11-01 05:15, short partial occultations), and LENZSPITZE-37, 99, 107 (Visibility, partial dimming): only the flux of the targets shows them. The error_value stays under K_MAD, and the targets are not rejected. The tools' data.py reads flux only for recent cameras (LENZSPITZE alone in the benchmark). A flux-drop rule would therefore serve one station, and on these one-measurement labels it would earn well under 1 point of the Obstruction Total. Seeing them on other stations needs flux, or the images.
  • The report says no label of the range is wrong. It removed LENZSPITZE-53 and rewrote -66 (now -119), and the labels file already reflects both.

Tools

  • sessions/LENZSPITZE_2026-10-23T2355_2026-11-01T1140_20261118T1049Z/tools/drift_days.py <detectors> <station> <from> <to> [targets]: daily levels, amplitude, whole-window drift and pieces of the slow drift, per target and axis. Worth keeping.
  • .../tools/per_label.py <detectors> <station> <labels> <from> <to> [family]: per label, instants found in its family and the families flagged instead. Worth keeping, as it is the per-label view the range score lacks.
  • .../tools/thermal_why.py <detectors> <station> <from> <to>: why the thermal wave is accepted or rejected (reproducible axes, sine R²). Worth keeping.
  • .../tools/shimmer_hours.py <detectors> <station> <from> <to> <iso start> <iso end>: per-hour heat-shimmer stats (agitated share, error ratio). Worth keeping.
  • .../tools/around.py <detectors> <station> <iso center> <minutes> <sensors>: error_value (MAD, ratio), flux and corr of sensors around an instant. Worth keeping.
  • .../tools/jumps_in.py <detectors> <station> <from> <to> <iso start> <iso end>: the jump episodes of displacement in an interval. Useful occasionally.
  • .../tools/drop_steady.py <detectors>: the one-off edit of S2. Not worth keeping.

Difficulties

  • Variant copies in the temporary folder find the tools' data.py only through cwd/tools/scripts, so the copies' benchmarks were run from the optimizer root.
  • The first variant edits of the "noobsc" and "own" copies failed, because a file has to be read before it is edited, so their first benchmark measured the unchanged state. They were rerun after the edits.
  • The first variants were made with inline sed/heredoc edits on the temporary copies, not with scripts in tools/. Those copies are throwaway, and their diffs are described in this file.