8.9 KiB
optimize: LENZSPITZE, 2026-10-23 → 2026-11-02
Result: modification kept Tools changed: scripts/thumbnails.py
The range
LENZSPITZE 2026-10-23T00:00Z → 2026-11-02T00:00Z, 63 labels, before → end (found, correct):
- Displacement: — → —; 0/2943 (0 %) → 0/27 (0 %)
- No data: 4/6 (67 %) → 4/6 (67 %); 4/4 (100 %) → 4/4 (100 %)
- Obstruction: 17/58 (29 %) → 17/58 (29 %); 17/486 (3 %) → 17/486 (3 %)
- Perturbation: 1/6 (17 %) → 1/6 (17 %); 1/426 (0 %) → 1/426 (0 %)
- Thermal displacement: 1342/1469 (91 %) → 1342/1469 (91 %); 1342/2611 (51 %) → 1342/2611 (51 %)
- Visibility: 817/1166 (70 %) → 817/1166 (70 %); 817/875 (93 %) → 817/875 (93 %)
Elsewhere
Total Displacement correct 18 → 41 %
NORDEND Displacement found 100 → 0 % (4 instants lost)
0 regression(s); complexity: 611 code lines, 48 constants → 606 code lines, 46 constants
What changed
- S1 (
f623b79),scripts/displacement.py: constantSIZE1.0 → 2.0; a slow drift over the whole window must now reach twice the median daily amplitude (thresholds.mdupdated). - S2 (
c8fb838), pruning: the Kendall-tau condition (STEADY= 0.6) removed from the whole-window test and the pieces, with its computations. - S3 (
466799f), pruning: constantDAYS= 5 removed; an axis needs at least two kept days, and the step condition still requires three days for a drift.
Upgrader's verdict: changed. Validator's verdict: keep.
For the user to decide
From the modification, "Limits":
- LENZSPITZE-89, 94, 49, 50, 59, 63, 109, 110, 111, 112, 113, 115 (Obstruction, 10-23 13:30 to 11-01 05:15, short partial occultations), and LENZSPITZE-37, 99, 107 (Visibility, partial dimming): only the
fluxof the targets shows them. Theerror_valuestays underK_MAD, and the targets are not rejected. The tools'data.pyreadsfluxonly for recent cameras (LENZSPITZE alone in the benchmark). A flux-drop rule would therefore serve one station, and on these one-measurement labels it would earn well under 1 point of the Obstruction Total. Seeing them on other stations needs flux, or the images. - The report says no label of the range is wrong. It removed LENZSPITZE-53 and rewrote -66 (now -119), and the labels file already reflects both.
From the modification, "For the user to decide":
- S1 sets the whole-window drift at 2 daily amplitudes. Untouched targets at 1.0 to 1.9 amplitudes are no longer flagged: 1001, 1010, 1012, 1016, 1018 of LENZSPITZE and PR16 of NORDEND, with no label on any of them. WILDSTRUBEL's PA3_2 (1.9) and PA_9 (1.6) drop out too, but PB2_2 (2.6) still covers WILDSTRUBEL-89. If the user reads a steady 1-to-2-amplitude creep over weeks as a Displacement ("keep watching it"), 1.5 would keep 1016 and the two WILDSTRUBEL PA drifts.
- LENZSPITZE-55 (LENZSPITZE, 10-28 11:00-14:05, Visibility, turbulence): the agitation is clear, but
error_valuedoes not rise against its calm. The detectors follow the families boundary ("the pose shaking without the error_value rising is not turbulence"), while the label calls it turbulence. Dropping the error criterion would need the user to change that boundary. - The
d andguard of_piecesis kept despite no figure change: it guards against the degenerate case of constant curves.
From the validation, "Reservations":
- NORDEND, Displacement, "found" 4/4 (100 %) → 0/4 (0 %). Before, these 4 labelled instants were "found" only because a whole-window Slow drift flagged 8549 instants (0 % correct). The labels NORDEND-276, NORDEND-309, NORDEND-94 and NORDEND-250 describe sudden jumps or camera steps, not a slow drift. They are this detector's business only by accident. Losing them is the noise of a few instants, and the reading is consistent.
Not fixed
- Target obscured during two consecutive mist nights (10-26 → 10-27, 9 sensors, ~115 instants of LENZSPITZE-101 and 181 of -42 flagged Obstruction). Tried two fixes. Counting only rejections shared by fewer than half of the sensors gave 4 regressions (NIEDERHORN, NORDEND, Total Obstruction found and correct).
MIN_DAYS2 → 3 gave 3 regressions (NIEDERHORN, WILDSTRUBEL, Total found). Target obscured is worth 1085 found instants elsewhere. - Thermal displacement bounds on LENZSPITZE: the slide fallback bridges nights over 10 days. Narrowing its merge gap to 12 h or 6 h gave regressions (LENZSPITZE found 92 → 81/76 %, WYOMING 51 → 36/33 %, Total found −3/−4 points). Detecting a wave carried by a minority of targets (8/31 here) would change the station-level rule (
SHARE,R2_MIN) for every station: not attempted in a small step. - Multi-hour Perturbation events around the visibility episodes (single-target jumps back after hours, outside the detected Visibility bounds).
- Lasting shifts of one target inside visibility episodes (4 instants) and the 8012 reference shifts (LENZSPITZE-105, 106, 108): small.
Reading tools
"What I decided":
thumbnails.py: changed. A sensor without anyx,yis left out with a printed line that names it and points to--zone. If no sensor is left and there is no--zone, the tool exits with a clear message.measurement()also needsyto be filled, not onlyx. One sentence is added to the docstring. Options and outputs are unchanged.quality.py: left. Making it reportcorrjumps would duplicateranges.py --instants.ranges.py: left.--rollingwith--instantsalready coversforgotten.py,scan.pyandrequal_instant.py, except for filtering by a labels file. The pointer belongs in the guide (proposed below).- Analyst scripts
requal_hourly.py,requal_thermal.py,drift.py,edges.py,amp.py: left where they are. They are hard-coded to this station and range, and mostly covered bysummary.py --step 1h,days.py --boundsandranges.py. Adding a tool for them would be a contraption for one range. - Nothing removed.
"What changed":
- S1, commit
9900604,scripts/thumbnails.py:- After
check("sensors", …), a new rule. Sensors with no measurement carrying bothxandyare printed (No x, y for … in the export: not placed (--zone X,Y,W,H looks at the scene around them).) and dropped from the sensor list. With no sensor left and no--zone, the tool exits withNo sensor left to centre a thumbnail on. measurement(): the filter goes fromm["x"] is not Nonetom["x"] is not None and m["y"] is not None.- Docstring: one more sentence saying such a sensor is left out and said so.
- After
data.py: unchanged.
Also proposed (tools.md, "For the user to decide"): a sentence for GUIDE.md, "quality" section, after the --outside bullet: "It sees only the image metrics: jumps of corr with a whole flux (a far reference that shifts, the basis that changes) come from ranges.py --rolling N --instants 2 on the same range." Not written, because GUIDE.md carries another session's uncommitted change.
Scripts of the agents
From the modification:
sessions/LENZSPITZE_2026-10-23T2355_2026-11-01T1140_20261118T1049Z/tools/drift_days.py <detectors> <station> <from> <to> [targets]: daily levels, amplitude, whole-window drift and pieces of the slow drift, per target and axis. Worth keeping..../tools/per_label.py <detectors> <station> <labels> <from> <to> [family]: per label, instants found in its family and the families flagged instead. Worth keeping, as it is the per-label view the range score lacks..../tools/thermal_why.py <detectors> <station> <from> <to>: why the thermal wave is accepted or rejected (reproducible axes, sine R²). Worth keeping..../tools/shimmer_hours.py <detectors> <station> <from> <to> <iso start> <iso end>: per-hour heat-shimmer stats (agitated share, error ratio). Worth keeping..../tools/around.py <detectors> <station> <iso center> <minutes> <sensors>: error_value (MAD, ratio), flux and corr of sensors around an instant. Worth keeping..../tools/jumps_in.py <detectors> <station> <from> <to> <iso start> <iso end>: the jump episodes ofdisplacementin an interval. Useful occasionally..../tools/drop_steady.py <detectors>: the one-off edit of S2. Not worth keeping.
From the validation: none.
From the tools upgrader:
sessions/LENZSPITZE_2026-10-23T2355_2026-11-01T1140_20261118T1049Z/tools/blank_xy.py: builds a test station folder from one day's export, withx,yemptied for chosen sensors and the images linked. Arguments:<station folder> <YYYYMMDD> <SENSOR,…> <new folder>. Run it withpython3 -I. Worth keeping to test any tool against a sensor without a position.
Errors
None.
- Files already modified: detectors: none; tools:
GUIDE.md(left as it is). - Detectors base
0adadd5bdc57725c765592b1001216b9c179126e;git -C detectors log --oneline 0adadd5..HEAD:466799f improve: S3 c8fb838 improve: S2 f623b79 improve: S1 - Tools base
7ada30a1ccb65af3a0d9a67c17e9a81451f322db;git -C tools log --oneline 7ada30a..HEAD:9900604 improve: S1