{"id": "NADELHORN-2026-11-12-D1", "debut": "2026-11-12T00:00Z", "fin": "2026-11-12T10:40Z", "categorie": "No data", "description": "Détecteurs : No data, tous les capteurs. No measurement in the export for 34 h 10 min (usually one every 5 min)."}
{"id": "NADELHORN-2026-11-12-D2", "debut": "2026-11-12T09:00Z", "fin": "2026-11-12T13:00Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal expansion, 35 capteurs. The camera support expands in the day heat; the curves are corrected for it. This daily wave is normal: nothing to do."}
{"id": "NADELHORN-2026-11-12-D3", "debut": "2026-11-12T10:40Z", "fin": "2026-11-12T22:40Z", "categorie": "Displacement", "description": "Détecteurs : Jump, not back yet, 9 capteurs. 9 targets shifted and have not come back yet. Check whether the structure moved: look at the images."}
{"id": "NADELHORN-2026-11-12-D4", "debut": "2026-11-12T10:40Z", "fin": "2026-11-12T23:35Z", "categorie": "Displacement", "description": "Détecteurs : Sudden jump, back to normal, c10_mon, c9_mon, c6_mon, c7_mon, c4_mon, c8_mon. 6 targets jumped and came back. The cause is not established: look at the images. The jumps of 5 targets in this period have the same cause."}
{"id": "NADELHORN-2026-11-12-D5", "debut": "2026-11-12T10:45Z", "fin": "2026-11-12T23:45Z", "categorie": "Obstruction", "description": "Détecteurs : Brief obstruction, m_c10_mon, m_c11_mon, m_c9_mon, m_ref4_mon, m_c12_mon, m_c5_mon, grisé. Something passed in front of 6 targets for a single measurement. Ignore this point on the curves."}
{"id": "NADELHORN-2026-11-12-D6", "debut": "2026-11-12T12:50Z", "fin": "2026-11-12T23:55Z", "categorie": "Obstruction", "description": "Détecteurs : Target obscured, c12_mon, grisé. c12_mon was hidden several times while the targets around it stayed clear. Ignore its curve in this period."}
{"id": "NADELHORN-2026-11-12-D7", "debut": "2026-11-12T13:00Z", "fin": "2026-11-12T23:55Z", "categorie": "Thermal displacement", "description": "Détecteurs : Camera thermal contraction, 35 capteurs. The camera support contracts as it cools down; the curves are corrected for it. This daily wave is normal: nothing to do."}