# improve: NORDEND, 2026-11-05 → 2026-11-06
**Result**: modification kept
## The range
NORDEND, 2026-11-05T00:00Z → 2026-11-06T00:00Z, 9 labels; before → end (found, correct)
- Displacement: 0/1 (0 %) → 0/1 (0 %); 0/3 (0 %) → 0/3 (0 %)
- Obstruction: 28/32 (88 %) → 28/32 (88 %); 28/60 (47 %) → 28/60 (47 %)
- Target issue: 0/96 (0 %) → 0/96 (0 %); —
- Thermal displacement: 53/95 (56 %) → 73/95 (77 %); 53/53 (100 %) → 73/73 (100 %)
- Visibility: —; 0/43 (0 %) → 0/43 (0 %)
## Elsewhere
`Total`, before → end (found, correct)
- Displacement: 5747/6346 (91 %); 5747/20444 (28 %) — unchanged
- No data: 75/836 (9 %); 75/100 (75 %) — unchanged
- Obstruction: 1044/4061 (26 %); 1044/3718 (28 %) — unchanged
- Target issue: 19080/22627 (84 %); 19080/19467 (98 %) — unchanged
- Thermal displacement: 10897/16142 (68 %) → 11986/16142 (74 %); 10897/14828 (73 %) → 11986/16069 (75 %)
- Visibility: 3412/7207 (47 %); 3412/4442 (77 %) — unchanged
Other changed lines:
- JUNGFRAU, Thermal displacement: 1544/2557 (60 %) → 2300/2557 (90 %); 1544/1786 (86 %) → 2300/2654 (87 %)
- NORDEND, Thermal displacement: 4769/7667 (62 %) → 5066/7667 (66 %); 4769/5097 (94 %) → 5066/5411 (94 %)
- SNCF01, Thermal displacement: 1218/1726 (71 %) → 1254/1726 (73 %); 1218/1275 (96 %) → 1254/1334 (94 %)
## What changed
- S1 (`3ea6b3e`), `scripts/thermal_displacement.py`: new constant `RETURN = 0.05`; the return of the thermal wave (contraction) now goes on until the hourly gap profile falls under `RETURN` times the amplitude, after midnight if needed, at most to the next day's start, instead of stopping at `EDGE` = 0.1, which now only bounds the start of the wave.
Upgrader: **changed**. Validator: **keep**.
## For the user to decide
From the modification, "Limits":
- NORDEND-231 (2026-11-05T00:45Z → 01:30Z, Obstruction), NORDEND-233 (03:15Z → 03:45Z, Obstruction), NORDEND-236 (23:00Z → 11-06 10:00Z, Obstruction): only the thumbnail shows that a cobweb thread lies on CTR03. From the measurements alone, it is a reference at its threshold that makes the base jump. Seeing the cause would take the image (a bright blurred band on the reference's spot).
- NORDEND-232 (03:00Z → 09:45Z) and NORDEND-235 (14:45Z → 15:15Z), Obstruction: by day, PR09's thread is only deduced from the night thumbnail.
- NORDEND-230 (Target issue, CTR01): the range command reads 3 days of history, too short for the `WEEK` (7 days) of a Degraded target. Over the whole label range it is found.
From the modification, "For the user to decide":
- NORDEND-243 (NORDEND, 2026-11-05 12:00, Displacement) against NORDEND-234 (Thermal displacement), whose description includes the same 12:00 jolt. The detectors absorb the one-measurement jump into the camera thermal wave, as 234 says. With this reading, the 1 Displacement instant of the range is never found.
- NORDEND-231 and NORDEND-233 (NORDEND, 2026-11-05 01:00 to 01:15 and 03:30, Obstruction). CTR03 is rejected just above its threshold, and the families document gives Visibility or Displacement for a reference at its threshold with nothing seen in front of it. The detectors read Visibility (absorbed into the Poor visibility). The labels are right because of the thumbnail.
From the validation, "Reservations": none.
## Not fixed
- **The false Poor visibility 00:45 → 09:30 and 13:30 → 15:00, and over the benchmark window 11-05 13:15 → 11-07 15:15.** It comes from 1 to 3 sensors high at a time, one reference among them, bounded by CTR01's chronic rejections. Four rules were tried in a copy, and each makes another station go back:
- (A) no Poor visibility when no instant has more than `FEW` sensors high: JUNGFRAU Visibility found 64 → 51 %, LENZSPITZE Obstruction correct 23 → 6 %;
- (C) the rejections of a target rejected more than half the time do not bound a Poor visibility: JUNGFRAU found 64 → 51 %, CLARIDEN 3 → 0 %;
- (T) the same, for the targets in a Target issue episode: JUNGFRAU, CLARIDEN and NORDEND Visibility found down;
- (S) heat shimmer agitation without the steps at a reference rejection, against the night heat shimmer on the CTR03 comb: WILDSTRUBEL Visibility 79 → 13 %.
On JUNGFRAU, nights with two references at their threshold are labelled Visibility, and the measurements alone give no general line between those and one reference hindered by a thread.
- **The early night of the 05/11 (01:00 → 06:30, end of NORDEND-229)** stays without the thermal wave. The return of the 04/11 contraction reaches `RETURN` at about 01:00, and the gap profile is no longer monotone at night (21:00 to 23:00 rise again).
- **NORDEND-232 (PR09)**: bounds only in part (Brief obstructions at 07:15 to 07:45 and 09:30); the rest of its rejections are inside the Poor visibility above.
- **The CTR03 rejection at 03:30 on the range** is not a Brief obstruction. PR04 and PR11 rise with it (the compensation runs on two references), so it fails the "fewer than `BRIEF_MIN` high sensors" guard. Over the benchmark window it already is one, so the gain would only be on the range.
## Tools
From the modification:
- `seances/NORDEND_2026-11-05T0600_2026-11-05T1200_20261116T1028Z/tools/raw_episodes.py <detectors> <station> FROM TO [detectors]`: the raw episodes of each detector (before classification) on a range plus 3 days of history. Worth keeping.
- `.../tools/high_sensors.py <detectors> <station> FROM TO SHOW_FROM SHOW_TO`: per instant, the sensors visibility.py calls high, the rejected ones, and the median MAD gap (point 8). Worth keeping for Visibility diagnoses.
- `.../tools/sensor_values.py <detectors> <station> SENSORS FROM TO [MEDIAN_FROM]`: error_value (×median, ×threshold), corr_x and corr_y of a few sensors. Worth keeping.
- `.../tools/thermal_gaps.py <detectors> <station> FROM TO`: the hourly gap profile used for the thermal bounds, on corr and on raw positions. Useful for thermal bounds.
- `.../tools/events_in_window.py <detectors> <station> FROM TO SHOW_FROM SHOW_TO`: classifies a long window, as the benchmark does, and shows the events of a sub-window. Worth keeping: range runs and benchmark runs differ (history, medians).
- `.../tools/bench_diff.py BEFORE AFTER`: the changed lines between two benchmark outputs, with regressions over 2 points flagged. Worth keeping as a workflow tool.
From the validation: none.
## Errors
none. Files already modified: none. Base: `e7c03e73041c81a7d338fb08ef16dad8eb8e9a84` (branch `main`).
```