Files
T

7.6 KiB

Modification

Verdict: changed Changed: scripts/thumbnails.py data.py: unchanged

What the analyst used

  • Tools: inventory.py (range, then for distances and mm/px), overview.py (range and 24-26/10, common, residuals, --rigid on 29/10), days.py --bounds --night 22-4 --smoothing 5, metrics.py, quality.py --common --step 1d and --labels … --outside, ranges.py --columns corr_x,corr_y --rolling 12 --merge 0min (requalification), thumbnails.py (sensors, and --zone over the whole image), whole images through ls | grep.
  • Its own scripts (scripts/): scan.py (per instant: rejections, retained references, pose, low flux, sensors off their rolling median by more than K own noises), edges.py, amp.py, drift.py (15-min medians against a base window), forgotten.py (instants where at least N sensors jump, outside the non-thermal labels), requal_instant.py (deviation of every target from its ±12 local level at an instant, in own noise), requal_hourly.py / requal_thermal.py (hourly median against a level window), requal_measure.py, build_labels.py, report_table.py, requal_write.py.
  • What got in its way ("Difficulties"): thumbnails.py --sensors with a sensor whose x, y are empty stopped on a Python traceback (min() iterable argument is empty); quality.py --outside lists only image-metric drops, so it found the shifts of a far reference and the jumps with a whole flux with its own scan (forgotten.py).

Diagnosis

  • thumbnails.py: a requested sensor with no filled x, y anywhere in the export makes measurement() call min() on an empty sequence, and the tool crashes. This happens in sensor mode and also in --zone mode (the crosses). check() only catches unknown names. On today's data the case cannot be reproduced on LENZSPITZE, because the re-pump of 2026-11-18 dropped 1023 and 8019 from the exports, so the tool now reports them as unknown sensors. The defect is still in the code for any station whose export leaves x, y empty for a sensor. I reproduced it on a test copy (below).
  • quality.py --outside only covers the image metrics, which is its job. To list the instants where several corr jump outside the labels, ranges.py --rolling N --instants 2 already does most of what forgotten.py / scan.py did. The guide does not point from one to the other. The fix would be one sentence in GUIDE.md, which I could not commit (see "Not fixed").

What I decided

  • thumbnails.py: changed. A sensor without any x, y is left out with a printed line that names it and points to --zone. If no sensor is left and there is no --zone, the tool exits with a clear message. measurement() also needs y to be filled, not only x. One sentence is added to the docstring. Options and outputs are unchanged.
  • quality.py: left. Making it report corr jumps would duplicate ranges.py --instants.
  • ranges.py: left. --rolling with --instants already covers forgotten.py, scan.py and requal_instant.py, except for filtering by a labels file. The pointer belongs in the guide (proposed below).
  • Analyst scripts requal_hourly.py, requal_thermal.py, drift.py, edges.py, amp.py: left where they are. They are hard-coded to this station and range, and mostly covered by summary.py --step 1h, days.py --bounds and ranges.py. Adding a tool for them would be a contraption for one range.
  • Nothing removed.

What changed

  • S1, commit 9900604, scripts/thumbnails.py:
    • After check("sensors", …), a new rule. Sensors with no measurement carrying both x and y are printed (No x, y for … in the export: not placed (--zone X,Y,W,H looks at the scene around them).) and dropped from the sensor list. With no sensor left and no --zone, the tool exits with No sensor left to centre a thumbnail on.
    • measurement(): the filter goes from m["x"] is not None to m["x"] is not None and m["y"] is not None.
    • Docstring: one more sentence saying such a sensor is left out and said so.

Why

  • Asking for thumbnails of a sensor that has no position in the export crashed the whole sheet with a traceback, including the other sensors and the --zone mode. Now the sensor is named and skipped, the sheet of the others is drawn, and the analyst is pointed to --zone.

Checks

Checks: none. Trials, on the range, outputs in sessions/LENZSPITZE_2026-10-23T2355_2026-11-01T1140_20261118T1049Z/work/tools/:

  • Test copy built by tools/blank_xy.py data/LENZSPITZE 20261025 1006 <tmp>/LENZSPITZE: the 25/10 export with x, y of 1006 emptied, images linked. It lives in a temporary folder, now deleted.
  • Before (HEAD version) on the test copy, --sensors 1006,1018: ValueError: min() iterable argument is empty.
  • After, --sensors 1006,1018 --times 2026-10-25T05:01Z,2026-10-25T06:01Z --radius 40: one No x, y for 1006 line, then the 1018 sheet (LENZSPITZE_thumbnails_1018_250501-250601.png, checked with Read: two thumbnails, spot centred). rc 0.
  • After, --sensors 1006 alone: the line, then No sensor left to centre a thumbnail on., rc 1, no traceback.
  • After, --sensors 1006,1018 --zone 1200,1000,600,400: the line, then the zone sheet with only 1018 crossed (LENZSPITZE_thumbnails_zone1200-1000-600-400_1018_250601.png, checked with Read). rc 0.

Report commands rerun: 3, no failure. report.md cites no command. These are the analyst's thumbnails.py sheets, rebuilt from the names of the PNGs in its work/thumbs/, run on the real station with --out …/work/: sensors 1006,1018,1002,1009 on 25/10 05:01-07:00 (checked with Read, identical layout), sensors 1011,1017,1012,1006 at six times, and the whole-image --zone 0,0,3088,2064 at four times.

For the user to decide

  • A sentence for GUIDE.md, "quality" section, after the --outside bullet: "It sees only the image metrics: jumps of corr with a whole flux (a far reference that shifts, the basis that changes) come from ranges.py --rolling N --instants 2 on the same range." I did not write it. GUIDE.md carries another session's uncommitted change, which I was told neither to commit nor to revert.

Not fixed

  • The guide pointer above, from quality.py --outside to ranges.py --rolling --instants, for the same reason.
  • The restriction to instants outside the labels of a file (what forgotten.py added) has no equivalent in ranges.py. A --labels F option for --instants would need its guide entry in the same change, so it is blocked for the same reason. It may also not be worth a new option, since --outside T1/T2 already exists for one episode.

Limits

  • The original crash (1023) cannot be reproduced on today's LENZSPITZE data: the re-pump dropped 1023 and 8019 from the exports. The fix was tried on a test copy with one sensor's x, y emptied.

Tools

  • sessions/LENZSPITZE_2026-10-23T2355_2026-11-01T1140_20261118T1049Z/tools/blank_xy.py: builds a test station folder from one day's export, with x, y emptied for chosen sensors and the images linked. Arguments: <station folder> <YYYYMMDD> <SENSOR,…> <new folder>. Run it with python3 -I. Worth keeping to test any tool against a sensor without a position.

Difficulties

  • GUIDE.md was already modified by another session and must not be committed. Every fix that needs a guide sentence (the CLAUDE.md rule: a new option enters the guide in the same change) was therefore out of reach. I kept to a fix that needs no guide change and put the rest under "For the user to decide".
  • The case in the evidence (1023) no longer exists in the data after the re-pump, so I built a test copy to reproduce it.
  • The output folder already holds files from the detectors upgrader (tools/, modification.md). My script sits next to theirs in tools/.