auto: the analysts verified the labels of 32 periods (11 stations, up to 14 days each): 710 labels -> 835, 587 unchanged; one analysis folder per period with its report (section Verification)

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
maximeandClaude Opus 5.5 committed 2026-11-17 15:13:44 +01:00
1 parent df979301b5
commit 2a5d87659b
279 files changed
+10758 -710

No files matched your search

@@ -0,0 +1,44 @@
# Labels: FLORIDA, 2026-10-11T09:45Z → 2026-10-22T03:15Z (UTC)
Verification of the 23 existing labels: 23 kept, 0 corrected, 0 removed, 5 added. The work was cut short by the usage limit: the checks listed under "Not checked" were not done.
Weather: there is no `weather/` folder for FLORIDA, so no weather is available.
## Verdict per old id
- FLORIDA-23 kept: r1_r is rejected at 10:00 and there is no pose at that instant (inventory).
- FLORIDA-24, 25, 26, 28, 31, 33, 36, 38, 44 kept. In the hourly pose (metrics.py), pan, tilt and scale follow the housing temperature. They start and come back within one or two measurements of the bounds (pan near -0.033 at night and -0.05 to -0.056 at the peak; scale from 1.0005 to 1.0015).
- FLORIDA-41 kept, with a doubt. In the hourly pose, the tilt starts falling and the scale rising from 08:00, before the gap at 09:00 (tilt 0.0098 at 07:00, 0.0057 at 08:00, 0.0026 at 10:00). The cycle may therefore start around 07:45 rather than 10:45. This was not checked at the native step.
- FLORIDA-27, 29, 32, 34, 35, 40, 42 kept: their bounds match the gaps listed by the inventory exactly. The claims about other stations were not re-checked.
- FLORIDA-30 kept (not re-checked at the native step).
- FLORIDA-37 and FLORIDA-39 kept: they cover all the rejections of p1_r, r1_r, Sellette 4, Sellette 5 and Pont Ernen on the 18th and 19th, and the missing poses.
- FLORIDA-43 kept: Sellette 5 is rejected at 05:30 and 05:45 and is back at 06:00.
- FLORIDA-45 kept: the last rejections are r1_r at 18:15 and Pont Ernen at 18:00. From 18:30 the pose is back, at the cold level. After that, Sellette 4's corr_x stays a little lower (about 0.075 against 0.11 the night before), which is one or two noise widths: not labeled.
- Spanning FLORIDA-1 and FLORIDA-14: consistent with the rejections of Sellette 6 and Massif 2 in the range (inventory).
## 1. My labels (added)
### 2026-10-12T00:30Z → 01:00Z, 01:45Z → 03:00Z, 03:45Z → 04:30Z, 06:15Z → 06:45Z, 22:15Z → 22:45Z
- **Phenomenon of the catalogue**: closest is "a target latches onto another spot", here applied to a reference; no exact match.
- **Precedents**: JUNGFRAU-7 and FLORIDA-51 (a reference poorly seen at night distorts the pose: Visibility). Not followed, because here p1_r's error_value does not rise.
- **Family**: Obstruction, because the cause is a local point beside one spot, not the whole scene. The nature of the point is not established: medium confidence.
- **Measured**: the jumps are at 00:45, 02:00, 02:45, 04:00 and 06:30 on the 12th, then 22:30. Sellette 4 corr_x rises by about 0.15 to 0.2, which is 5 to 9 noise widths. In the rigid fit on the targets (`overview.py --rigid` from 00:30), p1_r moves by about -0.1 to -0.19 px in dx while the targets stay still. p1_r's error_value stays flat (0.38 to 0.46).
- **Images**: the fixed-frame thumbnails at 01:00, 02:00, 03:00 and 04:00 show a small bright point at the upper left of p1_r at 01:00 and 03:00 (no jump), absent at 02:00 and 04:00 (jump). Copied to `p1_r_point.png`.
- **Confidence**: medium.
## 2. What I left without a label
- Isolated deviations of 3 to 4 noise widths (14/10 21:00, 21/10 21:15–22:45, and a few others): too small.
- The night of 21–22: the pose sits at a colder level that matches the temperature (tilt +0.02 and scale 1.0002 at 16–17 °C, the same relation as on the other nights). The corrected curves are flat apart from the small offset of Sellette 4 noted above.
## 3. The documentation
- The `--rigid` mode of `overview.py` was decisive: it showed that the reference moves, not the targets.
- Outside the range: FLORIDA-46 says "the camera does not move", but at 03:30 on the 22nd the pose jumps and Sellette 5 jumps for one measurement too.
## Not checked (cut short)
- FLORIDA-41 start at the native step.
- FLORIDA-30 at the native step.
- The other stations for the No data labels.
## Difficulties
- The usage limit cut the verification short.
## Sources read
instructions/analyst.md, tools/GUIDE.md, tools/DATA.md, labeling/families.md, labeling-rules.md, reading-rules.md, stations.md, labeling/auto/FLORIDA.jsonl (labels around the range), precedents.py, inventory, overview (with rigid), metrics, days, ranges, scripts/native.py, scripts/uncovered.py, thumbnails of 12/10.
@@ -0,0 +1,28 @@
{"start": "2026-10-11T09:45Z", "end": "2026-10-11T10:15Z", "family": "Visibility", "description": "r1_r, one of the only two references of the station, sees its error_value rise above the threshold for the duration of one measurement, in the morning: it is rejected and the camera is no longer registered. The corrected curves are then computed on p1_r alone: the corr_x of Sellette 5 and Sellette 4 jump a little and return at the next registration. Pont Ernen, the twin of r1_r, leaves its usual zero when it is not rejected too. Raw positions of the targets without a step. Cause not established. With a single reference, no measurement is possible: data of the range not to be trusted; this is not a movement. If it repeats, check the prism r1_r.", "review": "2026-11-17"}
{"start": "2026-10-11T09:45Z", "end": "2026-10-11T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T00:30Z", "end": "2026-10-12T01:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps later this night, labeled apart. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T01:45Z", "end": "2026-10-12T03:00Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement, then again a little later while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back in between only halfway, fully after the second. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 01:00, 02:00 and 03:00. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T03:45Z", "end": "2026-10-12T04:30Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back over the next two. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Seen on the thumbnails of 03:00 and 04:00. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T06:15Z", "end": "2026-10-12T06:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same jumps earlier this night, labeled apart. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-12T07:45Z", "end": "2026-10-12T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day, the corr_y of Sellette 4 a little, and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-12T22:15Z", "end": "2026-10-12T22:45Z", "family": "Obstruction", "description": "At night, the raw position of the reference p1_r, one of the only two references of the station, shifts for one measurement while the targets do not move in the image (rigid fit on the targets) and its error_value does not rise: the camera pose jumps (pan, tilt, scale) and the corr_x of Sellette 4 and Sellette 5 jump clearly upward together, their corr_y a little, then come back at the next one. On the thumbnails of the hours of this night, a small bright point just beside the spot of p1_r is there at the measurements without a jump and absent at those with a jump: the measurement of p1_r is disturbed by this neighbouring point; its nature is not established. Same signature as the jumps of the previous night; no image at that minute. It is not a movement of the structure: points to ignore."}
{"start": "2026-10-13T08:45Z", "end": "2026-10-13T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-14T01:15Z", "end": "2026-10-14T01:45Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; the station nevertheless synchronizes at that moment and its voltage is normal: it is running, the measurement is missing; measurements resume at the next one. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
{"start": "2026-10-14T08:45Z", "end": "2026-10-14T20:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T01:45Z", "end": "2026-10-15T02:45Z", "family": "No data", "description": "Two measurements absent half an hour apart, with a single measurement between them, for all sensors, and no image at those moments; the station nevertheless synchronizes at those moments and its voltage is normal: it is running, the measurements are missing. This one-measurement gap in the night, around 02:00 UTC, falls on the same measurement at FLORIDA and SNCF01 on 09, 14 and 15/10, and only on them; other stations have the same night gap around the same hour in other weeks (JUNGFRAU and NORDEND in early September): a common cause outside the station, at night, is probable; it is not established. Nothing to do on the station if it does not get worse.", "review": "2026-11-17"}
{"start": "2026-10-15T04:00Z", "end": "2026-10-15T09:00Z", "family": "Displacement", "description": "On the morning of the 15th, the corr_x of Sellette 5 returns to its level from before the rain of the 8th, and that of Sellette 4 partly: this is the return of the shift taken on the 9th, labeled separately. The error_value of r1_r rises again from the 15th, and the housing temperature has risen since the 13th. Cause not established; small, without established movement of the structure: to be monitored.", "review": "2026-11-17"}
{"start": "2026-10-15T07:45Z", "end": "2026-10-15T22:45Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 and, a little, that of Sellette 4 go down during the day, until the measurements stop in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-15T22:45Z", "end": "2026-10-16T10:45Z", "family": "No data", "description": "No measurement for any sensor during the night of 15 to 16, all the curves are missing; no image either, and no system metric over the range. The voltage is normal just before and just after; when the metrics return, a few entries were waiting to be sent. The gap starts at the same time, around 23:00, on the nine stations that were measuring then (LENZSPITZE only has its first measurements in the middle of that night, WILDSTRUBEL is already stopped), and their metrics stop at the same time on most of them; measurements and metrics resume at different times depending on the station, most of them in late morning. JUNGFRAU, whose metrics continue, accumulates unsent entries all night, sent in late morning, and yet its measurements for the night are missing from the data: a common cause outside the stations (transmission or reception of the data), not a shutdown of the stations; it is not established. The curves are missing over the range; nothing to do on the station if it does not repeat.", "review": "2026-11-17"}
{"start": "2026-10-16T10:45Z", "end": "2026-10-16T21:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corrected curves show almost nothing of it (measurements resumed in late morning). Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-16T13:30Z", "end": "2026-10-16T14:00Z", "family": "No data", "description": "One measurement absent for all sensors, a few hours after the resumption of the 16th, and no image at that moment; the station nevertheless synchronizes at that moment, normal voltage. The same gap falls at the same moment on the other stations measuring at that time (JUNGFRAU, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-16T14:15Z", "end": "2026-10-16T14:45Z", "family": "No data", "description": "One measurement absent for all sensors, three quarters of an hour after the previous one, and no image at that moment; normal voltage around it. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, LENZSPITZE, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-17T09:45Z", "end": "2026-10-17T23:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_y of Sellette 5 rises a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-18T05:00Z", "end": "2026-10-18T08:00Z", "family": "Visibility", "description": "End of a night with reduced visibility: the error_value of all the targets and of p1_r rises; p1_r (with Sellette 3), Sellette 4, Sellette 5, Massif 2 and Sellette 6 are rejected at times, the camera is no longer registered for four measurements, and the kept measurements jump. 06:00 thumbnails: all the spots smaller and weaker than the night before, nothing in front; probably dampness or mist, cause not established. Back at daybreak, Sellette 4 the last. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
{"start": "2026-10-18T08:45Z", "end": "2026-10-18T19:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corrected curves of Sellette 4 and Sellette 5 show almost nothing of it. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-18T19:30Z", "end": "2026-10-19T02:15Z", "family": "Visibility", "description": "Start of a night with reduced visibility: from 19h45, the error_value of p1_r rises, the camera pose goes wrong and the corr of Sellette 4 and Sellette 5 jumps; from 21h, Sellette 4, Sellette 5 and Sellette 6 are rejected almost over the whole range, p1_r (with Sellette 3) and Massif 2 most of the time, r1_r twice: the camera is almost no longer registered and the curves are missing; the kept measurements of Massif 2 and Sellette 6 jump. After the rejections end, the corr of Sellette 4 and Sellette 5 stay agitated until about 2h. 22:00 thumbnails: smaller and weaker spots, image of that hour without obstacle; cause not established (dampness probable). Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
{"start": "2026-10-19T09:00Z", "end": "2026-10-19T10:15Z", "family": "No data", "description": "Four measurements absent for all sensors, and no image; the station nevertheless synchronizes within the hour and the voltage is normal. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station.", "review": "2026-11-17"}
{"start": "2026-10-19T10:45Z", "end": "2026-10-19T22:00Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 goes down a little during the day and returns in the evening. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-19T20:45Z", "end": "2026-10-19T21:15Z", "family": "No data", "description": "One measurement absent for all sensors, and no image at that moment; measurements resume at the next one. The same gap falls at the same moment on the other stations measuring at that time (CLARIDEN, JUNGFRAU, LENZSPITZE, NIEDERHORN, NORDEND, SNCF01): a common cause outside the station (transmission or reception of the data), not a failure of the station; it is not established. The curves are missing over the range; nothing to do on the station. The hourly metrics of BREITHORN, MICHIGAN and NEBRASKA are also missing at 21:00.", "review": "2026-11-17"}
{"start": "2026-10-20T05:15Z", "end": "2026-10-20T06:00Z", "family": "Obstruction", "description": "Sellette 5 alone loses its spot for the duration of two measurements: on the fixed-frame thumbnails of 05:30 and 05:45, its spot has disappeared (present at 05:15 and 06:00) and the measurement latches onto the neighboring spot, that of Sellette 6: very high error_value, measurements rejected, its curve is missing. Sellette 4 and the references remain well seen; a small spot with no sensor, above Sellette 4, disappears at the same moments. What hides them is not visible. Nothing to do, points to ignore.", "review": "2026-11-17"}
{"start": "2026-10-20T09:45Z", "end": "2026-10-20T15:15Z", "family": "Thermal displacement", "description": "Thermal cycle of the day: with the rise of the housing temperature, the camera pose drifts (mostly the pan) until the middle of the afternoon, then returns at the end of the day; the corr_x of Sellette 5 and Sellette 6 goes down a little during the day, until the poor-visibility episode of the afternoon. Deduced: the camera movement follows the housing temperature, ordinary error_value outside the other episodes. Thermal movement of the camera (and perhaps of the pipe carrying the targets): normal, nothing to do.", "review": "2026-11-17"}
{"start": "2026-10-20T15:15Z", "end": "2026-10-21T18:30Z", "family": "Visibility", "description": "Long episode of poor visibility while the housing temperature drops: Sellette 4 and Sellette 5 rejected from the afternoon of the 20th, then through the night and the whole day of the 21st p1_r (with Sellette 3) and r1_r (with Pont Ernen) are rejected in turn: the camera is almost no longer registered, most of the curves are missing, and the kept measurements (Massif 2, Sellette 6, Pont Ernen) jump strongly. Seen on the 06:00 image on the 21st: scene veiled, wet leaves; 10:00 thumbnails: weak spots. Rain or mist. Not a movement: curves of the range to ignore.", "review": "2026-11-17"}
Binary file not shown.

After

Width:  |  Height:  |  Size: 110 KiB

@@ -0,0 +1,43 @@
# FLORIDA: check of the labels from 11 to 22 October
You asked me to check the 23 existing labels of this range.
## In short
All 23 labels hold. I added 5 short labels. On the night of the 11th to the 12th, and once on the evening of the 12th, a reference was measured wrongly and made Sellette 4 and Sellette 5 jump for one measurement each time. No real movement of the structure is seen.
## Verification
Kept 23, corrected 0, removed 0, added 5.
- Added: 12/10 00:30–01:00, 01:45–03:00, 03:45–04:30, 06:15–06:45, 22:15–22:45. The reference p1_r is measured at a slightly wrong position, and the targets jump with it.
- FLORIDA-41: kept, but its start (10:45) may be late. The camera already seems to move from about 08:00, before the gap in the data. This is still to be checked.
- Spanning labels FLORIDA-1 and FLORIDA-14: nothing wrong seen within the range.
## What happened
On the night of the 11th to the 12th, the reference p1_r was measured slightly off at single measurements: at 00:45, 02:00, 02:45, 04:00 and 06:30, then at 22:30 on the 12th. Each time, the corrected curves of Sellette 4 and Sellette 5 jump clearly and come back at the next measurement. The targets themselves do not move in the image. On the camera images, a small bright point next to p1_r is there at the hours without a jump and missing at the hours with one. The cause is likely, but what this point is remains unknown.
![p1_r thumbnails](p1_r_point.png)
Look at the small point at the upper left of p1_r: present at 01:00 and 03:00, absent at 02:00 and 04:00, the hours of the jumps.
## What to do
Nothing on site for now. If these jumps come back, look near the reference p1_r for a light or reflection.
## Not established
- What the small point next to p1_r is.
- The exact start of the thermal cycle on the 19th (FLORIDA-41).
- FLORIDA-30 was not re-checked in detail.
- The other stations were not re-read for the No data labels.
## Labels
| Start (UTC) | End (UTC) | Family | Targets | In a few words |
|---|---|---|---|---|
| 12/10 00:30 | 12/10 01:00 | Obstruction | p1_r, Sellette 4, Sellette 5 | reference measured off for one point |
| 12/10 01:45 | 12/10 03:00 | Obstruction | same | two such jumps |
| 12/10 03:45 | 12/10 04:30 | Obstruction | same | one jump |
| 12/10 06:15 | 12/10 06:45 | Obstruction | same | one jump |
| 12/10 22:15 | 12/10 22:45 | Obstruction | same | one jump |
| (23 existing labels kept unchanged) | | | | |
@@ -0,0 +1,6 @@
{
"station": "FLORIDA",
"start": "2026-10-11T09:45Z",
"end": "2026-10-22T03:15Z",
"hints": "Verify the existing labels of the range (work/existing.jsonl): keep, correct, remove, add."
}
@@ -0,0 +1,32 @@
"""Print native corr_x/corr_y/error_value of chosen sensors and the pose between two instants."""
import sys, csv, glob
sys.path.insert(0, 'tools/scripts')
start, end = sys.argv[1], sys.argv[2]
sensors = sys.argv[3].split(',')
cols = sys.argv[4].split(',') if len(sys.argv) > 4 else ['corr_x', 'corr_y', 'error_value']
rows = {}
for f in sorted(glob.glob('data/FLORIDA/displacement/FLORIDA_advanced_*.csv')):
for r in csv.DictReader(open(f)):
t = r['time_utc'][:16].replace(' ', 'T') + 'Z'
if not (start <= t <= end): continue
if r['sensor_name'] in sensors:
rej = r['error_value'] and r['error_threshold'] and float(r['error_value']) > float(r['error_threshold'])
rows.setdefault(t, {})[r['sensor_name']] = (r, rej)
pose = {}
for f in sorted(glob.glob('data/FLORIDA/camera/FLORIDA_camera_*.csv')):
for r in csv.DictReader(open(f)):
t = r['time_utc'][:16].replace(' ', 'T') + 'Z'
if start <= t <= end: pose[t] = r
def fm(v):
try: return f"{float(v):8.3f}"
except: return " -"
print('time ' + ' | '.join(f"{s[:10]:>10} " + ' '.join(c[:6] for c in cols) for s in sensors) + ' | pan tilt scale')
for t in sorted(rows):
out = []
for s in sensors:
if s not in rows[t]: out.append(' missing'); continue
r, rej = rows[t][s]
out.append(('R' if rej else ' ') + ' '.join(fm(r[c]) if not (rej and c.startswith('corr')) else ' rej' for c in cols))
p = pose.get(t)
ps = f"{float(p['median_pan']):.4f} {float(p['median_tilt']):.4f} {float(p['median_scale']):.5f}" if p else 'no pose'
print(t, ' | '.join(out), '|', ps)
@@ -0,0 +1,34 @@
"""Instants where Sellette 4/5 corr deviate from a rolling local level (or a non-Target-issue sensor is rejected), not covered by an existing label."""
import csv, glob, json, statistics as st, sys
D = 'labeling/auto/analyses/FLORIDA_2026-10-11T0945_2026-10-22T0315/work/existing.jsonl'
labels = [json.loads(l) for l in open(D)]
S, E = '2026-10-11T09:45Z', '2026-10-22T03:15Z'
K = float(sys.argv[1]) if len(sys.argv) > 1 else 4
data = {}
for f in sorted(glob.glob('data/FLORIDA/displacement/FLORIDA_advanced_*.csv')):
for r in csv.DictReader(open(f)):
t = r['time_utc'][:16].replace(' ', 'T') + 'Z'
if not (S <= t <= E): continue
data.setdefault(t, {})[r['sensor_name']] = r
times = sorted(data)
def cov(t, fam=None):
return [l['id'] for l in labels if l['start'] < t < l['end'] or (l['start'] <= t <= l['end'])]
flags = {}
for s in ['Sellette 4', 'Sellette 5']:
for c in ['corr_x', 'corr_y']:
ser = [(t, float(data[t][s][c])) for t in times if s in data[t] and data[t][s][c] not in ('', None)
and float(data[t][s]['error_value']) <= float(data[t][s]['error_threshold'])]
vals = [v for _, v in ser]
noise = st.median(abs(vals[i+1]-vals[i]) for i in range(len(vals)-1))
for i, (t, v) in enumerate(ser):
nb = vals[max(0, i-8):i] + vals[i+1:i+9]
d = (v - st.median(nb)) / noise
if abs(d) > K: flags.setdefault(t, []).append(f"{s[-1]}{c[-1]}{d:+.0f}")
for t in times:
for s in ['p1_r', 'r1_r', 'Sellette 4', 'Sellette 5', 'Pont Ernen', 'Sellette 3']:
r = data[t].get(s)
if r and float(r['error_value']) > float(r['error_threshold']): flags.setdefault(t, []).append(f"{s}:REJ")
for t in sorted(flags):
c = [i for i in cov(t)]
nonthermal = [i for i in c if next(l for l in labels if l['id']==i)['family'] != 'Thermal displacement']
print(t, ' '.join(flags[t]), '| covered by', ','.join(c) or 'NONE')