# Station Guide — Charging
|
|
|
|
CAUTION
|
|
The system tolerates a maximum input voltage of 26 V on both the power-supply connector
|
|
and the optional passive PoE input. Never connect a standard IEEE PoE source (802.3af,
|
|
802.3at or 802.3bt), as the standard PoE voltages of 48 V and above may damage the
|
|
charge controller.
|
|
CAUTION
|
|
The centre pin of the barrel connector is positive. If you are not using an AIMsight-supplied
|
|
power solution, always verify the connector polarity before connection, especially when
|
|
using third-party adapters such solar panels with MC4 connectors or adapters.
|
|
For mains-powered operation, connect the supplied power supply to an electrical outlet, then
|
|
connect it to the camera. This operating mode is recommended for charging the battery between
|
|
mobile deployments or when power is available at the monitoring site. In this configuration, the
|
|
battery remains connected and acts as an internal backup power source (UPS) in case of a
|
|
temporary power interruption.
|
|
For autonomous field operation, the camera can be connected to a solar panel. We recommend
|
|
using a standard 12 V solar panel; in most cases, a generic 100 W panel provides sufficient
|
|
charging capacity. Install the panel in a location with good sun exposure and orient it
|
|
appropriately for the site conditions.
|
|
The battery charges automatically whenever a suitable external power source is connected.
|
|
Charging performance depends on the available input power, battery state of charge, and
|
|
ambient conditions. For reliable operation, ensure that the external power source remains within
|
|
the specified voltage range and is capable of supplying adequate current.
|
|
NOTE
|
|
After a deep discharge (battery voltage below 12 V), the camera may not restart immediately.
|
|
To prevent repeated restart attempts caused by an insufficient charge level, the system
|
|
remains off until the battery voltage reaches approximately 12.6 V before powering up again.
|
|
While charging, verify that the charge-status LED is red. Once the battery has recovered to
|
|
the required voltage, the system will start automatically, provided that it is switched on.
|
|
|
|
Source : AIMsight Station Guide, rév. 1.5
|