# Station Guide — Image Mode and Target Preset
|
|
|
|
• Single with infrared light: captures one infrared-illuminated image per measurement and is
|
|
generally suited to dynamic measurements requiring a higher acquisition rate.
|
|
• Differential: combines multiple images to improve the contrast of reflective targets and is
|
|
generally suited to quasi-static monitoring or difficult detection conditions.
|
|
Pattern Preset selects the target configuration used to calculate displacement. When (use active
|
|
preset) is selected, the schedule uses the preset active at execution time. A later change to the
|
|
active preset may therefore change which targets the schedule processes. Select a named
|
|
preset when the schedule must always use a fixed target configuration.
|
|
CAUTION
|
|
Before enabling an automatic schedule, verify that the reference patterns have been saved
|
|
correctly and that the reference image represents the required displacement zero.
|
|
|
|
Source : AIMsight Station Guide, rév. 1.5
|